← Back to CMP brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

6037B EPICON T-800 QD High-build Epoxy Phenolic Tank Coating

Quick Specs

6037B EPICON T-800 QD High-build Epoxy Phenolic Tank Lining belongs to Epoxy. A single coat by airless spray can achieve a dry film thickness of 75–160 µm. Parameters on this page: Volume Solids 65 ± 2% [by volume] (ISO:3233), Dry Film Thickness 75–160 µm, Theoretical Spreading Rate 0.115–0.246 L/m². Comparable models from the same brand: 6033 EPICON T-800 HS High-build Epoxy Phenolic Tank Lining, 6037 EPICON T-800 High-build Epoxy Phenolic Tank Lining, 6035 EPICON T-800 HOLDING PRIMER Epoxy Phenolic Resin Temporary Anti-corrosive Primer.

Parameter source: CMP original technical data sheet (TDS) “6037B EPICON T-800 QD High-build Epoxy Phenolic Tank Lining”; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids65 ± 2% [by volume] (ISO 3233)
Dry Film Thickness75–160 µm
Theoretical Spreading Rate0.115-0.246 L/m2
VOC359 g/L (Method 24)
Density / Specific Gravity1.36 g/ml (ISO: 2811)
Number of ComponentsTwo-component
ThinnerEPOXY THINNER B
Mixing RatioBase : curing agent = 84:16 (by volume)
Colour / AppearanceGrey, light grey, red-brown

Browse Similar Models by CategoryThis model belongs to: Epoxy, Phenolic

FAQ

How many components does 6037B EPICON T-800 QD have?
6037B EPICON T-800 QD is a two-component product; use after mixing at the ratio given in the "Application Data" table on this page.
What is the mixing ratio of 6037B EPICON T-800 QD?
The mixing ratio of 6037B EPICON T-800 QD is Base : Hardener = 84:16 (by volume).
What dry film thickness is typically applied for 6037B EPICON T-800 QD?
The conventional dry film thickness of 6037B EPICON T-800 QD is 75–160 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of 6037B EPICON T-800 QD?
The theoretical spreading rate of 6037B EPICON T-800 QD is 0.115–0.246 L/m²; actual consumption is adjusted for substrate roughness, application loss and colour hiding power.
What is the volume solids of 6037B EPICON T-800 QD?
The volume solids of 6037B EPICON T-800 QD is 65 ± 2% [by volume] (ISO:3233).
What is the VOC of 6037B EPICON T-800 QD?
The VOC of 6037B EPICON T-800 QD is 359 g/L (Method 24).
What thinner is used for 6037B EPICON T-800 QD?
Recommended thinner for 6037B EPICON T-800 QD: EPOXY THINNER B.
What is the flash point of 6037B EPICON T-800 QD?
The flash point of 6037B EPICON T-800 QD is Base 17.5 °C, Hardener 7.5 °C; storage, transport and application shall follow the product safety data sheet.
How long does 6037B EPICON T-800 QD take to dry?
Drying time of 6037B EPICON T-800 QD under standard conditions: Drying Time Touch Dry; actual results are affected by temperature, film thickness and ventilation.
Which standards are involved for 6037B EPICON T-800 QD?
As recorded in the technical data on this page: remove the damaged areas by abrasive means to at least the Sa2 1/2 standard (ISO 8507-1 2007), or with power tools to St3 (ISO 8507-1:2007). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can 6037B EPICON T-800 QD be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

EPICON T-800 QD is a high-build epoxy phenolic coating with excellent physical properties such as strong adhesion, tough film and abrasion resistance, and with excellent chemical resistance to salt water, fresh water, petroleum products, crude oil, alkaline substances and weak acids. Suitable as a protective coating for tank interiors. A single coat by airless spray can achieve a dry film thickness of 75–160 µm. Can be applied at low temperatures.

Technical data

TypeHigh-Build Epoxy Phenolic Tank Coating
UseSuitable as a topcoat for oil tanks, chemical tanks and the like

Documents

Mixing RatioBase : curing agent = 84:16 (by volume)
ColourGrey, light grey, red-brown
Flash PointBase 17.5 °C, curing agent 7.5 °C
Density1.36 g/ml (ISO: 2811)
Volume Solids65 ± 2% [by volume] (ISO 3233)
Volatile organic compound content359 g/L (Method 24)
Theoretical spreading rate0.115-0.246 L/m2
ThicknessWFT 115–246 µm, DFT 75–160 µm

(dry film 125 µm)

Temperature-5 °C0 °C5 °C10 °C20 °C
Drying TimeSurface Dry36 h16 h3.5 h2 h1 h
Hard Dry156 h78 h24 h20 h8 h
Recoat intervalAt least156 h78 h24 h20 h16 h
At most*28 days28 days21 days14 days
At most**10 days10 days7 days
Pot life20 h12 h8 h6 h3 h
Induction Time120 min60 min30 min20 min10 min

Application conditions

Application methodAirless spray, brush, roller
Weather: temperatureMinimum 10 °C
HumidityMaximum 85% RH; steel temperature at least 5 °C above the dew point
Airless spray: viscosity1.0-1.8Pa.S
NozzleGraco619, 621, 623
Paint output pressure14.7-17.7 Mpa
Spray gun speed60–80 cm/s
ThinnerEPOXY THINNER B
Thinning0–10% by volume

Recommended surface preparation

NewbuildingFollow the shipyard standards. Consult your CMP representative for advice.
Repair and maintenanceRemove oil, grease and the like. Remove salts and other contaminants with high-pressure fresh water, then dry completely. Remove
Damaged areas to at least Sa2 1/2 (ISO 8507-12007) or prepare with power tools to St 3 (ISO 8507-1:2007).
Rinse with waterConsult your CMP representative for advice.

Surface Preparation

The type and degree depend on the actual condition of the material and the required performance.

Optimum results can be achieved even on lightly corroded or damp steel surfaces.

Use standards consistent with the Worldwide Marine Specifications.

Preceding coatEPICON T-800 HOLDING PRIMER, EPICON T-800, EPICON T-800 QD, CERABOND 2000
Subsequent coatEPICON T-800, EPICON T-800 QD
PackagingTwo-component

Note: 1. In confined spaces or restricted spaces at low temperature, ventilation is necessary to remove volatilised solvent and promote film formation during application and drying.

2. Stir the base with an electric stirrer to a uniform state, then thoroughly stir all of the curing agent with the base. Finally add an appropriate amount of thinner and mix thoroughly.

3. Excessive solvent may reduce sag resistance. 4. Mix only the amount of paint that can be used within the specified pot life.

5. *(1) Shade netting is recommended over the coating surface to avoid direct sunlight through manholes or other openings.

If the coating surface has been directly exposed to sunlight, the above “**” indicates the maximum recoat interval

6. on steelDew point + minimum 5 °C
on the filmDew point + minimum 3 °C. Volume solids, volatile organic content and density are theoretically calculated from a representative formulation without thinner.

Values vary with formulation for different colours.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating, phenolic coating

View all CMP models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery