← Back to CMP brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

6037 EPICON T-800 High-build Epoxy Phenolic Tank Coating

Quick Specs

6037 EPICON T-800 High-build Epoxy Phenolic Tank Coating is an epoxy coating. A protective coating for tank interiors, suitable for COT PSPC. Parameters on this page: volume solids 65 ± 2% [by volume] (ISO 3233); dry film thickness 75–160 µm; theoretical spreading rate 0.115–0.246 L/m². Comparable products from the same brand: 6033 EPICON T-800 HS High-build Epoxy Phenolic Tank Coating, 6037B EPICON T-800 QD High-build Epoxy Phenolic Tank Coating, 6035 EPICON T-800 HOLDING PRIMER Epoxy Phenolic Resin Temporary Anticorrosive Paint.

Source: CMP original technical data sheet (TDS) '6037 EPICON T-800 High-build Epoxy Phenolic Tank Coating'. Spreading rate and other values converted from the TDS; for reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids65 ± 2% [by volume] (ISO 3233)
Dry Film Thickness75–160 µm
Theoretical Spreading Rate0.115-0.246 L/m2
VOC359 g/L (Method 24)
Density / Specific Gravity1.36 g/ml (ISO: 2811)
Number of ComponentsTwo-component
ThinnerEPOXY THINNER B
Mixing RatioBase : curing agent = 84:16 (by volume)
Colour / AppearanceGrey, light grey, red-brown

Browse Similar Models by CategoryThis model belongs to: Epoxy, Phenolic

FAQ

How many components does 6037 EPICON T-800 contain?
6037 EPICON T-800 is a two-component product. Mix to the ratio shown in the Application Data table on this page before use.
What is the mixing ratio of 6037 EPICON T-800?
Mixing ratio of 6037 EPICON T-800: base : hardener = 84:16 (by volume).
What is the typical dry film thickness of 6037 EPICON T-800?
Typical dry film thickness of 6037 EPICON T-800: 75–160 µm; final value depends on the coating system and design requirements.
What is the theoretical spreading rate of 6037 EPICON T-800?
Theoretical spreading rate of 6037 EPICON T-800: 0.115–0.246 L/m²; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of 6037 EPICON T-800?
Volume solids of 6037 EPICON T-800: 65 ± 2% [by volume] (ISO 3233).
What is the VOC of 6037 EPICON T-800?
VOC of 6037 EPICON T-800: 359 g/L (Method 24).
Which thinner is recommended for 6037 EPICON T-800?
Recommended thinner for 6037 EPICON T-800: EPOXY THINNER B.
What is the flash point of 6037 EPICON T-800?
Flash point of 6037 EPICON T-800: 17.5 °C (base), 7.5 °C (hardener). Storage, transport and application per the product safety data sheet.
How long does 6037 EPICON T-800 take to dry?
Drying time of 6037 EPICON T-800 under standard conditions: touch dry; actual values depend on temperature, film thickness and ventilation.
Which standards apply to 6037 EPICON T-800?
As recorded in the technical data on this page: remove the damaged areas by abrasive means to at least the Sa2 1/2 standard (ISO 8507-1 2007), or with power tools to St3 (ISO 8507-1 2007). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can 6037 EPICON T-800 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

EPICON T-800 is a high-build epoxy phenolic coating with strong adhesion, tough film, abrasion resistance and other high physical properties, plus high chemical resistance to saltwater, fresh water, petroleum products, crude oil, alkalis and weak acids. A protective coating for tank interiors, suitable for COT PSPC. One airless spray coat can reach a dry film thickness of 75–160 µm.

Technical data

TypeHigh-Build Epoxy Phenolic Tank Coating
UseSuitable as a topcoat for oil tanks, chemical tanks and the like

Documents

Mixing RatioBase : curing agent = 84:16 (by volume)
ColourGrey, light grey, red-brown
Flash PointBase 17.5 °C, curing agent 7.5 °C
Density1.36 g/ml (ISO: 2811)
Volume Solids65 ± 2% [by volume] (ISO 3233)
Volatile organic compound content359 g/L (Method 24)
Theoretical spreading rate0.115-0.246 L/m2
ThicknessWFT 115–246 µm, DFT 75–160 µm

(dry film 125 µm)

Temperature10 °C20 °C30 °C40 °C
Drying TimeSurface Dry2.5 h1.5 h30 min15 min
Hard Dry24 h12 h6 h4 h
Recoat intervalAt least24 h16 h14 h8 h
At most*28 days21 days14 days10 days
At most**10 days7 days5 days3 days
Pot life7 h5 h3 h1.5 h

Application conditions

Application methodAirless spray, brush, roller
Weather: temperatureMinimum 10 °C
HumidityMaximum 85% RH; steel temperature at least 5 °C above the dew point
Airless spray: viscosity1.0-1.8Pa.S
NozzleGraco619, 621, 623
Paint output pressure14.7-17.7 Mpa
Spray gun speed60–80 cm/s
ThinnerEPOXY THINNER B
Thinning0–10% by volume

Recommended surface preparation

NewbuildingFollow the shipyard standards. Consult your CMP representative for advice.
Repair and maintenanceRemove oil and grease. Remove salts and other contaminants with high-pressure clean water, then dry
Fully. Remove damaged areas by abrasive blasting to at least Sa 2½ (ISO 8507-12007) or with power
power tools to St 3 (ISO 8507-12007).
Rinse with waterConsult your CMP representative for advice.

Surface Preparation

The type and degree depend on the actual condition of the material and the required performance.

Optimum results can be achieved even on lightly corroded or damp steel surfaces.

Use standards consistent with the Worldwide Marine Specifications.

Preceding coatEPICON T-800 HOLDING PRIMER, EPICON T-800, EPICON T-800 QD, CERABOND 2000
Subsequent coatEPICON T-800
PackagingTwo-component

Note: 1. In confined spaces or restricted spaces at low temperature, ventilation is necessary to remove volatilised solvent and promote film formation during application and drying.

2. Stir the base with an electric stirrer to a uniform state, then thoroughly stir all of the curing agent with the base. Finally add an appropriate amount of thinner and mix thoroughly.

3. Excessive solvent may reduce sag resistance. 4. Mix only the amount of paint that can be used within the specified pot life.

5. *(1) Shade netting is recommended over the coating surface to avoid direct sunlight through manholes or other openings.

If the coating surface has been directly exposed to sunlight, the above “**” indicates the maximum recoat interval

6. on steelDew point + minimum 5 °C
on the filmDew point + minimum 3 °C. 7. Volume solids, VOC content and density are theoretically calculated from a representative formulation without thinner. Values vary with colour formulation.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating, phenolic coating

View all CMP models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery