Epoxy High-build Coating ZD6311 is an epoxy coating. Suitable for the protection of steel and concrete in severely corrosive environments; can be used as an intermediate coat or as a topcoat for internal structures. Two-component high-solids epoxy coating composed of epoxy resin, pigments and fillers, amine hardener, and other components. Parameters on this page: volume solids 82.5 ± 3%, dry film thickness 75/125/200 µm, theoretical spreading rate 0.364 kg/m². Comparable products of the same brand: ZD6315 High-solids General-purpose Epoxy Coating (Chinese and English), ZD6340 Epoxy Coal Tar High-build Anticorrosive Coating, ZD6350 Solvent-free Epoxy Anticorrosive Coating.
Parameter source: ZINDN manufacturer's Technical Data Sheet (TDS) "Epoxy High-build Coating ZD6311"; spreading rate and other values are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 82.5 ± 3% |
|---|---|
| Dry Film Thickness | 75/125/200 µm |
| Theoretical Spreading Rate | 0.364 kg/m² |
| VOC | ≤150g/L |
| Density / Specific Gravity | 1.5 ± 0.1 |
| Number of Components | Two-component |
| Flash Point | >25 °C (components A, B and the mixture) |
| Thinner | ZX-06 Epoxy Thinner |
| Mixing Ratio | Component A (base) : Component B (curing agent) = 6:1 |
ZD6311 Epoxy High-build Coating
A two-component, high-solids epoxy composed of epoxy resin, pigments, fillers and an amine curing agent.
High water resistance and anticorrosive performance;
Good chemical and oil resistance;
Good adhesion, impact resistance and abrasion resistance;
For protection of steel and concrete in severely corrosive environments; may be used as an intermediate coat or as a topcoat for internal structures.
| Colour | Grey |
|---|---|
| Gloss | Matt |
| Volume Solids | 82.5±3% |
| Mixed density (kg/L) | 1.5±0.1 |
| Dry film thickness (µm) | Minimum 75 | Typical 125 | Maximum 200 |
| Wet film thickness (µm) | 91 | 152 | 242 |
| Theoretical spreading rate (kg/m²) | 0.136 | 0.227 | 0.364 |
| Practical Spreading Rate | Allowing for a suitable loss factor |
|---|---|
| VOC content | ≤150g/L |
| New steel | Remove grease from the surface, and rinse off salts and other contaminants with fresh water. Remove weld slag, grind sharp edges smooth, blast clean to Sa 2.5 (ISO 8501-1), with surface roughness Rz 50–100 µm. |
|---|---|
| Shop-primed surface | Welds, heat-corrected areas and damaged areas must be blast cleaned to Sa 2.5 (ISO 8501-1) or ground with abrasive discs to St 3. |
| Repair | Thoroughly remove grease from the surface, and wash off salts and other contaminants with high-pressure fresh water. |
| Concrete surface | Apply after sealing surface pores with a suitable sealer. |
| Other surfaces | Consult our company. |
The substrate surface temperature must be at least 5 °C and at least 3 °C above the dew point. Ample ventilation is required during application and drying in confined spaces.
Do not apply outdoors in adverse weather such as rain, fog, snow, strong wind and heavy dust;
| Mixing | This product is supplied as two containers forming one unit. Stir the base thoroughly with a power mixer, add the curing agent in the specified ratio, stir again with a power mixer, and add the recommended thinner to adjust to a suitable application viscosity. Once mixed, use within the specified pot life. |
|---|---|
| Thinner / Cleaning Solvent | ZX-06 Epoxy Thinner |
| Mixing ratio (by weight) | Component A (base) : Component B (curing agent) = 6:1 |
| Induction Time | No induction required |
| 5°C | 15°C | 25°C | 35°C |
| 4 h | 3 h | 2 h | 1.5 h |
| Application Methods | Airless spray is recommended; air spray is not recommended; brush and roller are recommended only for touch-up, small-area application or repair. |
|---|
| Application Methods | Unit | High-pressure airless spray | Brush/roller |
| Spray gun tip size | mm | 0.43~0.53 | —— |
| Spray pressure | kg/cm² | 150~200 | —— |
| Thinning quantity | % | 0~10 | 5~10 |
| Substrate surface temperature | 5°C | 15°C | 25°C | 35°C | ||
| Touch Dry | 16 h | 8 h | 4 h | 2 h | ||
| Hard Dry | 48 h | 24 h | 12 h | 6 h | ||
| Fully cured | 14 days | 10 days | 6 days | 4 days | ||
| Minimum recoat interval | 48 h | 24 h | 12 h | 6 h | ||
| Maximum recoat interval | Self-recoat | 14 days | 10 | days | 6 days | 4 days |
| Overcoat with topcoat | 30 days | 20 days | 14 days | 7 days |
Note: the above data are measured under well-ventilated conditions, at typical film thickness and 75% relative humidity, and are for reference only.
Actual drying times and the interval before recoating may be longer or shorter depending on film thickness, ventilation, humidity, the underlying paint, requirements for early handling and mechanical strength, and other factors. The coating must be fully cured before immersion service.
| Preceding | Over an approved primer or shop primer |
|---|---|
| Subsequent | Self-recoat or an approved topcoat |
| Packaging Specifications | Component A 24 kg, Component B 4 kg |
|---|---|
| Flash Point | >25 °C (components A, B and the mixture) |
| Storage conditions | Store in accordance with national regulations. Keep in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. |
| Shelf life | Shelf life is 1 year under good storage conditions. |
This product contains flammable materials; site safety must comply with the relevant national or local regulations. Read the safety labels on the packaging and the product Safety Data Sheet (MSDS).
Avoid inhaling solvent vapours and spray mist, avoid contact of paint with skin and eyes, and do not swallow the product. Take the necessary precautions and protective measures for fire prevention, explosion prevention and environmental protection. Use only in well-ventilated conditions. In confined or poorly ventilated areas, provide forced ventilation.
Waste disposal must comply with the relevant national or local regulations.
The information and data in this document are accumulated from our tests and practical experience and may serve as an application guide. Since the use of the product is generally beyond our control, we guarantee only the quality of the product itself. We reserve the right to modify this document without prior notice as the product is improved.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.