Epoxy Mastic ZD6311

Quick Specs

Epoxy High-build Coating ZD6311 is an epoxy coating. Suitable for the protection of steel and concrete in severely corrosive environments; can be used as an intermediate coat or as a topcoat for internal structures. Two-component high-solids epoxy coating composed of epoxy resin, pigments and fillers, amine hardener, and other components. Parameters on this page: volume solids 82.5 ± 3%, dry film thickness 75/125/200 µm, theoretical spreading rate 0.364 kg/m². Comparable products of the same brand: ZD6315 High-solids General-purpose Epoxy Coating (Chinese and English), ZD6340 Epoxy Coal Tar High-build Anticorrosive Coating, ZD6350 Solvent-free Epoxy Anticorrosive Coating.

Parameter source: ZINDN manufacturer's Technical Data Sheet (TDS) "Epoxy High-build Coating ZD6311"; spreading rate and other values are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids82.5 ± 3%
Dry Film Thickness75/125/200 µm
Theoretical Spreading Rate0.364 kg/m²
VOC≤150g/L
Density / Specific Gravity1.5 ± 0.1
Number of ComponentsTwo-component
Flash Point>25 °C (components A, B and the mixture)
ThinnerZX-06 Epoxy Thinner
Mixing RatioComponent A (base) : Component B (curing agent) = 6:1

Browse Similar Models by CategoryThis model belongs to: Epoxy

ZD6311 Epoxy High-build Coating

Product description

A two-component, high-solids epoxy composed of epoxy resin, pigments, fillers and an amine curing agent.

Key features

High water resistance and anticorrosive performance;

Good chemical and oil resistance;

Good adhesion, impact resistance and abrasion resistance;

Intended use

For protection of steel and concrete in severely corrosive environments; may be used as an intermediate coat or as a topcoat for internal structures.

Specification data

ColourGrey
GlossMatt
Volume Solids82.5±3%
Mixed density (kg/L)1.5±0.1

Typical film thickness and theoretical spreading rate

Dry film thickness (µm)Minimum 75Typical 125Maximum 200
Wet film thickness (µm)91152242
Theoretical spreading rate (kg/m²)0.1360.2270.364
Practical Spreading RateAllowing for a suitable loss factor
VOC content≤150g/L

Application instructions

Suitable substrates and surface preparation

New steelRemove grease from the surface, and rinse off salts and other contaminants with fresh water. Remove weld slag, grind sharp edges smooth, blast clean to Sa 2.5 (ISO 8501-1), with surface roughness Rz 50–100 µm.
Shop-primed surfaceWelds, heat-corrected areas and damaged areas must be blast cleaned to Sa 2.5 (ISO 8501-1) or ground with abrasive discs to St 3.
RepairThoroughly remove grease from the surface, and wash off salts and other contaminants with high-pressure fresh water.
Concrete surfaceApply after sealing surface pores with a suitable sealer.
Other surfacesConsult our company.

Application and curing conditions

The substrate surface temperature must be at least 5 °C and at least 3 °C above the dew point. Ample ventilation is required during application and drying in confined spaces.

Do not apply outdoors in adverse weather such as rain, fog, snow, strong wind and heavy dust;

Paint mixing

MixingThis product is supplied as two containers forming one unit. Stir the base thoroughly with a power mixer, add the curing agent in the specified ratio, stir again with a power mixer, and add the recommended thinner to adjust to a suitable application viscosity. Once mixed, use within the specified pot life.
Thinner / Cleaning SolventZX-06 Epoxy Thinner
Mixing ratio (by weight)Component A (base) : Component B (curing agent) = 6:1
Induction TimeNo induction required

Pot life after mixing

5°C15°C25°C35°C
4 h3 h2 h1.5 h

Application

Application MethodsAirless spray is recommended; air spray is not recommended; brush and roller are recommended only for touch-up, small-area application or repair.

Application parameters

Application MethodsUnitHigh-pressure airless sprayBrush/roller
Spray gun tip sizemm0.43~0.53——
Spray pressurekg/cm²150~200——
Thinning quantity%0~105~10

Drying/curing time and recoat interval

Substrate surface temperature5°C15°C25°C35°C
Touch Dry16 h8 h4 h2 h
Hard Dry48 h24 h12 h6 h
Fully cured14 days10 days6 days4 days
Minimum recoat interval48 h24 h12 h6 h
Maximum recoat intervalSelf-recoat14 days10days6 days4 days
Overcoat with topcoat30 days20 days14 days7 days

Note: the above data are measured under well-ventilated conditions, at typical film thickness and 75% relative humidity, and are for reference only.

Actual drying times and the interval before recoating may be longer or shorter depending on film thickness, ventilation, humidity, the underlying paint, requirements for early handling and mechanical strength, and other factors. The coating must be fully cured before immersion service.

Typical paint system

PrecedingOver an approved primer or shop primer
SubsequentSelf-recoat or an approved topcoat

Packaging, storage and handling

Packaging SpecificationsComponent A 24 kg, Component B 4 kg
Flash Point>25 °C (components A, B and the mixture)
Storage conditionsStore in accordance with national regulations. Keep in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed.
Shelf lifeShelf life is 1 year under good storage conditions.

Health, safety and environmental protection

This product contains flammable materials; site safety must comply with the relevant national or local regulations. Read the safety labels on the packaging and the product Safety Data Sheet (MSDS).

Avoid inhaling solvent vapours and spray mist, avoid contact of paint with skin and eyes, and do not swallow the product. Take the necessary precautions and protective measures for fire prevention, explosion prevention and environmental protection. Use only in well-ventilated conditions. In confined or poorly ventilated areas, provide forced ventilation.

Waste disposal must comply with the relevant national or local regulations.

Disclaimer

The information and data in this document are accumulated from our tests and practical experience and may serve as an application guide. Since the use of the product is generally beyond our control, we guarantee only the quality of the product itself. We reserve the right to modify this document without prior notice as the product is improved.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

FAQ

How many components does ZD6311 Epoxy High-build Coating have?
ZD6311 Epoxy High-build Coating is a two-component product. Mix according to the mixing ratio in the Application Data table on this page before use.
What is the mixing ratio of ZD6311 Epoxy High-build Coating?
The mixing ratio of ZD6311 Epoxy High-build Coating is Component A (Base):Component B (Hardener) = 6:1.
What is the typical dry film thickness of ZD6311 Epoxy High-build Coating?
Typical dry film thickness of ZD6311 Epoxy High-build Coating is 75/125/200 µm; the specific value depends on the coating system and design requirements.
What is the theoretical spreading rate of ZD6311 Epoxy High-build Coating?
The theoretical spreading rate of ZD6311 Epoxy High-build Coating is 0.364 kg/m²; actual consumption is adjusted according to substrate roughness, application loss, and colour hiding power.
What is the volume solids of ZD6311 Epoxy High-build Coating?
The volume solids of ZD6311 Epoxy High-build Coating is 82.5 ± 3%.
What is the VOC of ZD6311 Epoxy High-build Coating?
The VOC of ZD6311 Epoxy High-build Coating is ≤150 g/L.
What is the gloss of ZD6311 Epoxy High-build Coating?
The gloss of ZD6311 Epoxy High-build Coating is flat.
What thinner is used for ZD6311 Epoxy High-build Coating?
Compatible thinner for ZD6311 Epoxy High-build Coating: ZX-06 Epoxy Thinner.
What is the flash point of ZD6311 Epoxy High-build Coating?
The flash point of Epoxy High-build ZD6311 is >25 °C (components A, B and mixture); storage, transport and application shall comply with the product Safety Data Sheet.
How is ZD6311 Epoxy High-build Coating applied?
Application method for epoxy high-build coating ZD6311: airless spray is recommended; conventional air spray is not recommended; brush and roller application are recommended only for stripe coating, small areas or touch-up; surface preparation and coating systems are as described on this page.
Which standards apply to ZD6311 Epoxy High-build Coating?
As recorded in the technical data on this page: remove weld spatter, grind sharp edges smooth and blast clean to grade Sa2.5 (ISO8501-1), with a surface roughness Rz of 50-100 µm. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can ZD6311 Epoxy High-build Coating be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Similar models from the same brand — epoxy coating

View all ZINDN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery