← Back to ZINDN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

ZD6310-N01P Epoxy Oil-resistant Conductive Primer

Quick Specs

ZD6310-N01P Epoxy Oil-resistant Antistatic Primer is an epoxy paint, used as a primer. A two-component anti-corrosion coating based on epoxy resin and epoxy hardener, with non-carbon composite conductive filler, anti-corrosive pigments and additives. Parameters on this page: volume solids 82 ± 2%, dry film thickness 40/80/150 µm, theoretical spreading rate 4.8 m²/L. Comparable products of the same brand: ZD6317 Fast-drying Zinc Phosphate Epoxy Paint, Hot-dip Galvanizing Special Epoxy Primer ZD6180, Epoxy Sealer ZD1035.

Data source: ZINDN original Technical Data Sheet (TDS), "ZD6310-N01P Epoxy Oil-resistant Antistatic Primer"; spreading rate and other values are converted from the TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids82 ± 2%
Dry Film Thickness40/80/150 µm
Theoretical Spreading Rate4.8 m2/L
VOC~250 (tested per GB 30981.2-2025)
Density / Specific Gravity1.58 ± 0.1
Number of ComponentsTwo-component
Flash Point>25 °C (mixture)
ThinnerX-500 Epoxy Thinner
Mixing RatioComponent A (base) : Component B (curing agent) = 12.5:1 (by weight)

Browse Similar Models by CategoryThis model belongs to: Primer, Epoxy

ZD6310-N01P Epoxy Oil Resistant and StaticConductive Primer

Product description

A two-component anti-corrosion coating composed of epoxy resin, epoxy curing agent asthe base material, and non-carbon composite conductive fillers, anti-rust pigments, andadditives .

Key features

● Excellent adhesion, flexibility, and impact resistance ;

● Excellent oil and corrosion resistance, insoluble and non-swelling after use;

● Has excellent anti-static performance, coating resistivity of 108-1011 Ω

Recommended use

The anti-static and anti-corrosion protection of compartments and storage tanks loadedwith crude oil, gasoline, aviation gasoline, kerosene, naphtha, and benzene can also beused in other situations where static electricity is required.

Basic data

ColourGrey or iron red
ColorGrey or iron red
Solids content by mass82±2%
Mass solids82 ± 2%
Volume Solids72±2%
Volume solids72±2%
Typical mixed density (kg/L)1.58±0.1

Typical density (kg/L): 1.58 ± 0.1. Typical dry film thickness and theoretical spreading rate

MinimumTypicalMaximum
MinimumTypicalMaximum
Dry film thickness (µm)4080150
Wet film thickness (µm)55.5111208.3
Theoretical spreading rate (m²/L)1894.8
Theoretical spreading rate (m²/kg)11.395.693.03
Practical Spreading RateAllowing for a suitable loss factor
Practical spreading rateconsider appropriated loss factor
VOC content as supplied (g/L)~250 (tested per GB 30981.2-2025)
VOC(supplied,g/L)~250(follow GB 30981.2-2025)
Application instructionsApplication instruction
Suitable substrates and surface preparationSuitable substrate and treatment

Substrate condition

● Bare steel: Use a suitable cleaner to remove oil/grease, and rinse the surface with fresh water to remove salts and other contaminants. Remove welding slag, grind the weld seam and sharp edges, blast to Sa2.5 (ISO8501-1) to surface profile of Rz30 µ m~75 µ m(ISO8503-1) as optimal results, It is best to apply the coating within 4 hours after blasting.

● Shop primer: welds, pyrotechnic corrections, and damaged areas should be blasted to Sa2.5 (ISO8501-1), or power tool to St3.

● Primer: clean and dry without zinc salts or contaminants.

● Maintenance and Repair: Thoroughly remove surface oil/grease with appropriate cleaner, and remove salts and other contaminants with high-pressure fresh water. It is best to blast to remove rust and other loose substances, or power tools for rusty small areas.

Substrate temperature and application conditions

substrate temperature and application conditions

● The application environment temperature should be within 5-38 °C, the relative humidity should not exceed 85%, and the substrate temperature should be at least 3 °C above the dew point; Outdoor application is prohibited in adverse weather conditions such as rain, fog, snow, strong winds, and sandstorm etc;

● Attention to dry spraying at high temperatures. During application in narrow spaces and curing period, adequate ventilation is required;

● When the construction environment temperature is -5~5 °C, appropriate measures should be taken to ensure the normal curing of the paint film.

Paint mixing

Product mix

● Mixing: This product is available in two cans as one set. Before application, firstly stir the main part evenly with a mixer, adding the curing agent at the specified ratio, mix evenly with a mixer, and add an appropriate amount of thinner to adjust to the appropriate application viscosity. Once mixed, it must be used up within the pot life.

● Thinner/cleaner:Thinner X-500

● Mixing ration(by weight): A(main):B(cure agent)=12.5:1

Pot life after mixing (at suitable application viscosity)

Pot life (suitable application viscosity)

Paint temperature (°C)5°C15°C25°C35°C
Pot life (hours)5.5543

Application data

Application methodUnitAirless sprayAir sprayBrush/roller
Nozzle orificemm0.43~0.581.5~2.5——
Nozzle pressurekg/cm²150~2003~4——
Thinner*%0~1010~205~10

*Thinner usage depends on required thickness and application condition

Addition data

Over coating interval (@80 µm DFT)

Substrate temperature (°C)5152535
Surface dry (hrs)42130
Dry to handle (hrs)2416128
Minimum overcoating interval (self) (hrs)2416106
Maximum overcoating interval (self)No limit, but the chalking layer from long-term exposure shall be removed thoroughly before overcoating. No limit, but the surface should be roughened and fully cleaned after long-term exposure.

Note: the above data are measured under good ventilation, typical film thickness and relative humidity ≤ 75%, and are for reference only. Actual drying times and overcoating intervals may be shorter or longer, depending on film thickness, ventilation, humidity, the underlying coat, early handling requirements and mechanical strength.

Notice

above are typical data based on good ventilation, typical film thickness and relativehumidity ≤75%, just for reference only.

Real drying time base on impact of over coating interval, film thickness, ventilation,

humidity,undercoat, ahead of loading and unloading and mechanical strengthrequirement etc.

Adding too much thinner results in sag resistance reduction and slower cure.

Notification

● Previous coat:blasted at least Sa2.5

● Next coat: Epoxy oil resistant and static conductive topcoat.

● For details, please consult ZINDN company.

● Must use be used approved thinner.

● During the painting process, contact with water, acid, alkali, etc. is strictly prohibited.

● The appearance will lose gloss, whiten and turn to bad quality once the condensation, sudden temperature drop happened.

Package, storage and shelf lifepackage size

ComponentsA (base)B (curing agent)
Pack size20 L5 L
Container size20 L5 L
Pack size (weight)25 kg2 kg
Package size(weight)25 kg2 kg
Flash Point>25 °C (mixture)
Flash Point> 25 °C(Mixed)

Storage condition

● Must follow national rules. Should be dry, cool, good ventilation and away heat and fire. The container should be well sealed.

Shelf life

● 1 year at good storage condition. After this period the product must be inspected and approved prior to use.

Health, safety and environment

● The product contains flammable substances; site safety shall comply with the relevant national or local regulations. Note the safety labels on the packaging and read the material safety data sheet (MSDS).

● Avoid inhaling solvent vapour and spray mist, avoid skin and eye contact with the paint, and do not swallow the product. Take the necessary precautions for fire and explosion protection and environmental protection. Use the product in a well-ventilated area. In narrow or poorly ventilated spaces, provide forced ventilation.

● This product contains flammable components; the application site has to meet national safety and local government requirement. More details please read and

●Avoidsolventvaporandpaintmist,avoidcontactingskinandeyes,forbidden
swallowing,musthavenecessaryto havepreventionandprotectionfor fire,

exploration and environment protection solutions. Application under good ventilation,provide sufficient ventilation when in narrow space and in non-good air flow.

● Waste treatment has to follow national and local government requirement.

SoundBright

Declare

The product documents and data based our experiments and application experience, usefor application instruction. The application condition is usually out of our control; we onlywarrant product quality itself. ZINDN keeps the authority to modify for improvementwithout pre-notification to customers.

Version

The ZINDN Logo,and ZINDN remarks are properties of group of companies, all thirdparties are not allowed to use without permit.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

How many components does ZD6310-N01P have?
ZD6310-N01P is a two-component product; mix according to the ratio in the "Coating Data" table on this page before use.
What is the mixing ratio of ZD6310-N01P?
The mixing ratio of ZD6310-N01P is A (base) : B (hardener) = 12.5:1 (by weight).
What is the typical dry film thickness for ZD6310-N01P?
The typical dry film thickness of ZD6310-N01P is 40/80/150 µm; the exact value depends on the coating system and design requirements.
What is the theoretical spreading rate of ZD6310-N01P?
The theoretical spreading rate of ZD6310-N01P is 4.8 m²/L; actual consumption depends on substrate roughness, application losses and colour opacity.
What is the volume solids of ZD6310-N01P?
The volume solids of ZD6310-N01P is 82 ± 2%.
What is the VOC of ZD6310-N01P?
The VOC of ZD6310-N01P is ~250 (tested per GB 30981.2-2025).
What thinner is used with ZD6310-N01P?
Recommended thinner for ZD6310-N01P: X-500 epoxy thinner.
What is the flash point of ZD6310-N01P?
The flash point of ZD6310-N01P is >25°C (mixture); storage, transport and application shall follow the product Safety Data Sheet.
Which standards apply to ZD6310-N01P?
As recorded in the technical data on this page: GB 30981.2 (see the application instructions on this page); ISO8501 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can ZD6310-N01P be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Similar models from the same brand — primer, epoxy coating

View all ZINDN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery