Quick Specs

Interline 1046 Epoxy Phenolic Resin Paint belongs to epoxy paints. It provides internal anti-corrosion protection for steel storage tanks containing various products where static charge accumulation may occur, such as crude oil, unleaded gasoline blends, MTBE, and aromatic and aliphatic solvents. A two-component, chemical-resistant, high-solids, high-build phenolic epoxy resin lining coating with static dissipative properties. When used as a primer at a DFT of 80 µm (3.2 mil), Interline 1046 can withstand blasting for up to 14 days in semi-protected environments such as tank interiors. Parameters on this page: volume solids 76% ± 2%, DFT 100-150 µm (4-6 mil), theoretical spreading rate 6.08 m²/L.

Parameter source: AKZONOBEL original technical data sheet (TDS) 'Interline 1046 Epoxy Phenolic Resin Paint'; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids76% ± 2%
Dry Film Thickness100–150 µm (4–6 mils)
Theoretical Spreading Rate6.08 m²/L
VOC1.88 lb/gal (226 g/L) US EPA Method 24 21…
Density / Specific Gravity1.5 kg/L (12.5 lb/gal)
Number of ComponentsTwo-component
ThinnerNormally no thinning is required
Mixing Ratio3.8 parts : 1 part (by volume)
Colour / AppearanceGrey, INTERLINE 1046

Browse Similar Models by CategoryThis model belongs to: Epoxy, Phenolic

FAQ

How many components does Interline 1046 contain?
Interline 1046 is a two-component product. Mix according to the mixing ratio in the 'Coating Data' table on this page before use.
What is the mixing ratio of Interline 1046?
The mixing ratio of Interline 1046 is 3.8 parts : 1 part (by volume).
What DFT is typically applied for Interline 1046?
The typical DFT of Interline 1046 is 100-150 µm (4-6 mil), determined by the coating system and design requirements.
What is the theoretical spreading rate of Interline 1046?
The theoretical spreading rate of Interline 1046 is 6.08 m²/L; actual consumption is adjusted according to substrate roughness, application loss, and colour hiding power.
What is the volume solids of Interline 1046?
The volume solids of Interline 1046 is 76% ± 2%.
What is the VOC of Interline 1046?
The VOC of Interline 1046 is 1.88 lb/gal (226 g/L) US EPA Method 24 21….
What is the gloss of Interline 1046?
The gloss of Interline 1046 is not applicable.
What thinner is used for Interline 1046?
Recommended thinner for Interline 1046: usually no thinning is required.
How is Interline 1046 applied?
Application method for Interline 1046: suitable for airless spray, air spray, brush and roller; drying time and self-recoating interval; surface preparation and the coating system are as described on this page.
Which standards are involved for Interline 1046?
As recorded in the technical data on this page: GB 23985 (see the application instructions on this page); GB 30981.2 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Interline 1046 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product description

A two-component, chemical-resistant, high-solids, high-build phenolic epoxy lining with static dissipation.

Intended use

For corrosion protection of the inner walls of steel tanks holding various products where static accumulation may be a problem, such as crude oil, unleaded gasoline blends, MTBE and aromatic and aliphatic solvents

Application data

ColourGrey, INTERLINE 1046
GlossN/A
Volume Solids76% ± 2%
Typical thicknessDry film 100–150 µm (4–6 mils), equivalent to wet film 132–197 µm (5.3–7.9 mils)
Theoretical Spreading RateAt 125 µm dry film thickness and the stated volume solids: 6.08 m²/L; at 5 mils dry film thickness and the stated volume solids: 244 ft²/US gal
Practical Spreading RateAllowing for a suitable loss factor
Application MethodsSuitable for airless spray, air spray, brush, roller. Drying time; self-recoat interval
TemperatureSurface DryHard DryMinimumMaximum
10°C (50°F)9 h24 h15 days
15°C (59°F)8 h20 h15 days
25°C (77°F)4 h8 h15 days
40°C (104°F)3 h5 h10 days

Regulatory compliance data

Flash point (typical)Component A 42 °C (108 °F); Component B 54 °C (129 °F); mixed 43 °C (109 °F)
Product weight1.5 kg/L (12.5 lb/gal)
Volatile Organic Compounds1.88 lb/gal (226 g/L) US EPA Method 24 213 g/kg EC Solvent Emissions Directive content (EU Council Directive 2010/75/EU) 186 g/L Chinese National Standard GB 23985 Coating Hazard GB 30981.2-S-Pb≤1000-NC Complies with GB 30981.2-2025. For more detailed information, see the 'Product Characteristics' section.

Surface Preparation

All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2019.

Where necessary, remove weld spatter and grind welds and sharp edges smooth. Oil and grease must be removed in accordance with the SSPC-SP1 solvent cleaning standard.

Abrasive blast clean to at least Sa 2.5 (ISO 8501-1:2007) or SSPC-SP10.

Recommended surface roughness 50–75 µm (2–3 mils).

Interline 1046 shall be applied before oxidation of the steel occurs. If oxidation has occurred, the oxidized areas shall be re-blasted to meet the above standard.

Surface defects exposed by blast cleaning must be ground, filled or treated by another suitable method.

Where permitted by local VOC regulations, Interline 1046 (10-15% thinned) may be applied as a primer before surface oxidation occurs, at a DFT of 80 µm (3.2 mil). Alternatively, dehumidification methods may be used to maintain the blasting standard.

Areas with cracks, damage, welds, and similar defects shall be pre-treated to the specified standard (such as Sa2½ (ISO 8501-1:2007) or SSPC SP10, or cleaned with power tools to Pt3 (JSRA SPSS:1984) or SSPC SP11).

Application

MixingThis product is supplied in two containers forming one unit. Mix the two components in the specified ratio in one operation. Once mixed, use within the specified pot life.

(1) Stir the base (Component A) with a power mixer.

(2) Mix all of the curing agent (Component B) with the base (Component A) and stir thoroughly with a power mixer.

Mixing ratio3.8 parts : 1 part (by volume)
Pot life10°C (50°F)15°C (59°F)25°C (77°F)40°C (104°F)
3 h2 h1 h45 min
Suitable for airless spraySuitable nozzle tip size 0.48-0.58 mm (19-23 mil) and total paint pressure at the nozzle not less than 204 kg/cm² (2901 psi)
Air SpraySuitableSpray gunDeVilbiss MBC or JGA
Air nozzle704 or 765
(with pressure pot)NozzleE
BrushRecommendedTypical thickness 80 µm (3.2 mil)
Roller applicationRecommendedTypical thickness 50–75 µm (2.0–3.0 mils)
ThinnerInternational GTA220 (orNormally no thinning is required.

or International GTA415). In extreme cases, consult the local technical representative.

Do not thin beyond the requirements of local environmental regulations.

CleanerInternational GTA853 (or International GTA415)
Interruption of workDo not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with International thinner.

Once mixed, paint should not be resealed. If work is interrupted for too long, mix a fresh batch for application.

CleaningAll equipment should be cleaned immediately after use with International thinner. Flushing spray equipment periodically during the daily work is good working practice. Cleaning frequency depends on the volume sprayed, temperature and time spent, including delays.

All surplus paint and empty containers must be disposed of in accordance with the appropriate local regulations/laws.

Product Characteristics

Interline 1046 shall not be applied over unapproved primers or old paint films, as this may interfere with static dissipation performance.

Interline 1046 is generally specified as a two-coat system, with a thickness of 125 µm (5 mil) per coat and a total system DFT of 250 µm (10 mil). The exact system for this total DFT depends on the requirements of the end use. Consult International Paint for specific recommendations on tank lining application.

When used as a primer at a DFT of 80 µm (3.2 mil), Interline 1046 can withstand blasting for up to 14 days in semi-protected environments such as tank interiors. If moisture is present on the surface, oxidation will occur and re-blasting is required. Alternatively, if the recoat interval is observed and all surfaces are properly cleaned and pre-treated, a full coat may be applied before recoating with Interline 1046.

At temperatures below 15°C (59°F), an induction time of 15 min is recommended after mixing and before application of Interline 1046.

To achieve the maximum film thickness in one coat, airless spray is the ideal method. Application methods other than airless spray cannot achieve the required film thickness. With conventional air spray, several cross coats are required to achieve the maximum film thickness. Brush and roller are recommended for small areas only.

The temperature of the surface to be coated must be at least 3 °C (5 °F) above the dew point.

After the final coat is fully cured, a suitable non-destructive magnetic thickness gauge shall be used to measure the DFT of the coating system to verify the average total applied system thickness. The coating system shall be free of pinholes or other misses. The cured film shall be free of runs, sags, drips, inclusions, or other defects. All deficiencies and defects shall be corrected. Repaired areas shall be retested and cured as specified before being placed into service.

The coating achieves ideal chemical resistance only after full cure. The degree of cure depends on temperature, humidity and film thickness. Generally, at 250 µm (10 mils) total dry film thickness, full cure and ideal chemical resistance are achieved in 7–10 days at 25 °C (77 °F) and 50% relative humidity. At higher temperatures, curing shortens proportionally; at lower temperatures, it lengthens.

For storage of cargoes above ambient temperature, consult International Paint for further detailed advice.

Note: VOC values are typical and for guidance only. They may vary with colour and general production tolerances.

System compatibility

This is a self-overcoating coating and is not suitable for application over other primers. Interline 1046 shall only be recoated with itself and shall never be recoated with other products.

Supplementary information

For further information on the industry standards, terms and abbreviations used in this datasheet, see www.international-pc.comIn the following documents on the website: • Definitions and abbreviations • Surface preparation • Coating application • Theoretical and practical spreading rate. These sections are also available as separate publications on request.

Safety precautions

This product is intended for professional applicators in industrial use only.

All work, including the application and use of this product, must comply with the relevant national standards, laws and regulations on safety, health and environmental protection.

During application and the subsequent drying period, provide adequate ventilation to keep solvent concentrations within safe limits and prevent fire and explosion (for general drying times, see the product data sheet). Forced ventilation is required in confined spaces. During application and drying, personal ventilation and/or respiratory protection (e.g. air-fed hood or suitable filter mask) must also be provided. Take the necessary measures to prevent skin and eye contact with the coating (e.g. protective clothing, gloves, goggles, mask, barrier cream).

Before use, read and follow the Health and Safety section of the Material Safety Data Sheet and the application procedure for the product (for two-component coatings, those of the base and curing agent).

If welding or flame cutting is performed on metal substrate coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation.

The specific safety measures depend on the application method and working environment. If these warnings or instructions are not fully understood or cannot be strictly observed, do not use the product and consult the International Paint Protective Coatings division.

Packaging Specifications

Packaging SpecificationsComponent AComponent B
VolumePackagingVolumePackaging
20 L15.83 L20 L4.17 L5 L

For other packaging sizes, contact AkzoNobel.

Shipping weight

Packaging SpecificationsComponent AComponent B
20 L26.19 kg4 kg

Storage

Shelf lifeAt least 12 months at 25 °C (77 °F). Thereafter, inspection is required. Store in a dry, cool environment away from heat and sources of ignition.

Issue date

© 2026/5/26 AkzoNobel. All rights reserved.

All registered trademarks mentioned in this publication are licensed to or owned by AkzoNobel.

www.international-pc.com

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating, phenolic coating

View all AKZONOBEL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

Factory item number list (1 in total)

The factory product codes for Interline 1046 Epoxy Phenolic Resin Paint are as follows.Item No.is the most accurate form when ordering;Colour/colour codecorresponds to the actual colour (RAL, GSB are colour chart codes);Packaging SpecificationsFactory complete-set specification format. Colors not listed may be ordered against the colour card.

Item No.Colour / colour codePackaging Specifications
HTA660Grey20 L

This model has a total of1item numbers, all listed on this page; colours outside the table (including special colours and bulk packaging) can be confirmed by phone, delivery dates are advised according to the factory's current production schedule and stock. In the packaging specification, the "+" indicates the complete-set notation for two-component products (base + curing agent), subject to the factory specification; a "—" in the colour column denotes an auxiliary product, or that the item has no colour code in the factory system.

China production baseIndustrial & marine coatingsWorldwide delivery