Water-borne Nano-modified Fluorocarbon Topcoat ZDW3060 is a water-borne paint, used as a topcoat. Suitable for overcoating on previous coats such as acrylic or epoxy, used as a protective, highly decorative, weather-resistant topcoat for metal structures or concrete surfaces in various atmospheric environments. A self-cleaning, highly weather-resistant, water-borne two-component fluorocarbon topcoat made from water-borne hydroxy fluorocarbon emulsion, water, high-weather-resistance pigments and fillers, additives, hydrophilically modified hardener, etc. Parameters on this page: volume solids 47 ± 3%, dry film thickness 30/50/80 µm, theoretical spreading rate 0.213 kg/m². Comparable products of the same brand: Water-borne High-performance Fluorocarbon Topcoat ZDW3050, Water-borne Acrylic Topcoat ZD5100, Water-borne Acrylic Topcoat ZDW3051.
Data source: ZINDN original Technical Data Sheet (TDS), "Water-borne Nano-modified Fluorocarbon Topcoat ZDW3060"; spreading rate and other values are converted from the TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 47 ± 3% |
|---|---|
| Dry Film Thickness | 30/50/80 µm |
| Theoretical Spreading Rate | 0.213 kg/m² |
| VOC | ≤200g/L |
| Density / Specific Gravity | 1.25 ± 0.1 |
| Number of Components | Two-component |
| Flash Point | >95°C |
| Thinner | Deionised water (clean tools before the paint is touch dry; once touch dry, a glycol ether solvent may be used for tool cleaning… |
| Mixing Ratio | Component A (base) : Component B (curing agent) = 7:1 |
ZDW3060 Water-borne Nano-modified Fluorocarbon Topcoat
A self-cleaning, highly weather-resistant, water-borne two-component fluorocarbon topcoat made from water-borne hydroxy fluorocarbon emulsion, water, high-weather-resistance pigments and fillers, additives, hydrophilically modified hardener, etc. Fluorine content above 22%.
Excellent adhesion and gloss/colour retention, combining protection with high decorative function;
High dirt resistance;
Low VOC content, low odour, environmentally friendly.
Suitable for application over acrylic or epoxy previous coats, as a protective, highly decorative, weather-resistant topcoat for metal structures or concrete surfaces in various atmospheric environments.
| Colour | Various colours |
|---|---|
| Gloss | Flat |
| Volume Solids | 47±3% |
| Mixed density (kg/L) | 1.25±0.1 |
| Dry film thickness (µm) | Minimum 30 | Typical 50 | Maximum* 80 |
| Wet film thickness (µm) | 63.8 | 106 | 170 |
| Theoretical spreading rate (kg/m²) | 0.079 | 0.132 | 0.213 |
| Practical Spreading Rate | Allowing for a suitable loss factor |
|---|---|
| VOC content | ≤200g/L |
Remove all oil, grease and contaminants from the surface with a suitable cleaner; keep the surface clean, dry and free of contamination.
This product must be applied over the recommended primer or intermediate coat.
| Mixing | This product is supplied as two containers forming one unit. Stir the base thoroughly with a power mixer, add the curing agent in the specified ratio, stir again with a power mixer, and add the recommended thinner to adjust to a suitable application viscosity. Once mixed, use within the specified pot life. |
|---|---|
| Thinner / Cleaning Solvent | Deionised water (clean tools before the paint is touch dry; once touch dry, a glycol ether solvent may be used for tool cleaning) |
| Mixing ratio (by weight) | Component A (base) : Component B (curing agent) = 7:1 |
| Induction Time | No induction required |
| 5°C | 15°C | 25°C | 35°C |
| 4.5 h | 3.5 h | 3 h | 1.5 h |
| Application Methods | Airless spray or air spray is recommended; brush and roller are recommended only for touch-up, small-area application or repair. |
|---|
Use a soft brush or short-nap roller to minimise air entrapment.
| Application Methods | Unit | High-pressure airless spray | Air Spray | Brush/roller |
| Spray gun tip size | mm | 0.38~0.48 | 1.5~2.0 | —— |
| Spray pressure | kg/cm² | 150~200 | 3~4 | —— |
| Thinning quantity | % | 0~5 | 0~10 | 0~5 |
| Substrate surface temperature | 5°C | 15°C | 25°C | 35°C |
| Touch Dry | 1 h | 45 min | 30 min | 20 min |
| Hard Dry | 24 h | 12 h | 8 h | 4 h |
| Minimum recoat interval | 24 h | 12 h | 8 h | 4 h |
| Maximum recoat interval | 30 days, with the surface to be coated kept clean and dry |
|---|
Note: the above data are measured under well-ventilated conditions, at typical film thickness and 65% relative humidity, and are for reference only.
Actual drying times and the interval before recoating may be longer or shorter depending on film thickness, ventilation, humidity, the underlying paint, requirements for early handling and mechanical strength, and other factors. The coating must be fully cured before immersion service.
| Preceding paint | Various epoxy, polyurethane intermediate coats or anti-corrosive primers |
|---|
During application and drying/curing, the relative humidity must not exceed 80%.
With roller and brush application, several coats may be required to achieve full hiding, especially for certain lead-free bright colours such as yellow and orange.
| Packaging Specifications | Base 21 kg, hardener 3 kg |
|---|---|
| Flash Point | >95°C |
| Storage conditions | Store in accordance with national regulations. Keep at a temperature above 0 °C in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. |
| Shelf life | Shelf life is 1 year under good storage conditions. |
Site safety must comply with the relevant national or local regulations. Read the safety labels on the packaging and the product Safety Data Sheet (MSDS).
Avoid inhaling spray mist, avoid contact of paint with skin and eyes, and do not swallow the product. Take the necessary precautions and protective measures to protect the environment. Use only in well-ventilated conditions. In confined or poorly ventilated areas, provide forced ventilation.
Waste disposal must comply with the relevant national or local regulations.
The information and data in this document are accumulated from our tests and practical experience and may serve as an application guide. Since the use of the product is generally beyond our control, we guarantee only the quality of the product itself. We reserve the right to modify this document without prior notice as the product is improved.
| Version information | Published in June 2022; this data sheet supersedes all previous versions |
|---|
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.