China-based coatings exporter — industrial & marine protective coatings from China's production bases

Dedicated Epoxy Sealer XH4013

Quick Specs

Special Epoxy Sealer XH4013 is an epoxy coating. With excellent penetration, it can be used as a general-purpose sealer for porous substrates such as concrete, thermally sprayed zinc and thermally sprayed aluminium. Parameters on this page: volume solids 51 ± 2%, dry film thickness 30/40/50 µm, theoretical spreading rate 10 m²/L.

Parameter source: T&H manufacturer's Technical Data Sheet (TDS) "Dedicated Epoxy Sealer XH4013"; spreading rate and other values are converted from the TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids51 ± 2%
Dry Film Thickness30/40/50 µm
Theoretical Spreading Rate10 m2/L
VOC460g/L
Density / Specific Gravity1.2 kg/L
Number of ComponentsTwo-component
Flash Point25°C
Thinner0-5%
Mixing RatioBase : curing agent = 3:1 (by weight), 2:1 (by volume)

Browse Similar Models by CategoryThis model belongs to: Epoxy

FAQ

How many components does Special Epoxy Sealer have?
Special Epoxy Sealer is a two-component product. Mix according to the mixing ratio in the "Coating Data" table on this page before use.
What is the mixing ratio of Special Epoxy Sealer?
The mixing ratio of Special Epoxy Sealer is base : curing agent = 3:1 (by weight), 2:1 (by volume).
What dry film thickness is normally applied for Special Epoxy Sealer?
Special Epoxy Sealer is normally applied at 30/40/50 µm dry film thickness; the exact value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Special Epoxy Sealer?
The theoretical spreading rate of Special Epoxy Sealer is 10 m²/L; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of Special Epoxy Sealer?
The volume solids of Special Epoxy Sealer is 51 ± 2%.
What is the VOC of Special Epoxy Sealer?
The VOC of Special Epoxy Sealer is 460 g/L.
What is the gloss of Special Epoxy Sealer?
The gloss of Special Epoxy Sealer is N/A.
Which thinner is used for Special Epoxy Sealer?
The recommended thinner for Special Epoxy Sealer: 0–5%.
What is the flash point of Special Epoxy Sealer?
The flash point of Special Epoxy Sealer is 25 °C. Handle, store and apply in accordance with the product safety data sheet.
Which standards apply to Special Epoxy Sealer?
As recorded in the technical data on this page: before coating, all surfaces shall be assessed and prepared in accordance with ISO 8504:2000. Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Special Epoxy Sealer be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product Description

A two-component polyamide-cured epoxy sealer. With excellent penetration, it can be used as a general-purpose sealer for porous substrates such as concrete, thermally sprayed zinc and thermally sprayed aluminium.

Product Characteristics

Basic physical and chemical data

ColourGrey
GlossN/A
density1.2 kg/L
Volume Solids51±2%
Volatile Organic Compounds460g/L
Flash Point25°C
Mixing ratioBase : curing agent = 3:1 (by weight), 2:1 (by volume)

Application parameters

Typical dry film thickness40µm
Recommended dry film thickness30–50 µm, depending on system requirements
Induction time (20 °C)10-15min

Application Methods

Thinner quantity (by volume)Airless spray 0–5%Air spray 5–15%Roller or brush 0–5%
Recommended nozzle size0.38~0.53mm1.5~2.0mm/
Recommended spray pressure15~20MPa0.3~0.6MPa/
Application suitabilityRecommendedApplicableRecommended

*In high-temperature seasons, use a slow-drying thinner

Theoretical Spreading Rate

Dry film thickness (µm)304050
Wet film thickness (µm)6080100
Theoretical spreading rate (m²/L)16.712.510

Application data (typical dry film thickness 40 µm)

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
5°C6h24h8h24h
15°C4h12h6h12h/
25°C2h8h4h8h
40°C30min4h2h4h

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

All surfaces to be coated must be clean, dry and free of contaminants. Before application, all surfaces must be assessed and prepared in accordance with ISO 8504:2000. Abrasive blast clean to Sa 2½, with surface roughness 40–75 µm. Before rust removal, remove all oil and weld spatter and grind welds and sharp edges. Areas of the coating damaged mechanically and showing localised rust must be spot blast cleaned to Sa 2½ or cleaned with power tools to St 3 before local repair. If this coating is to be applied over an approved zinc dust primer old film, thoroughly remove any chalking or zinc salts from the zinc dust coating before applying this product. For concrete protection, the concrete must be cured, with moisture content and surface condition meeting the relevant requirements.

Precautions

1. During application, ensure good ventilation and exhaust, keep away from ignition sources, and wear a mask, gloves and other protective equipment; adequate ventilation shall also be maintained during curing. 2. Before mixing the two components, stir the base thoroughly with a power tool, then add the curing agent and mix uniformly; adjust the thinner amount according to application requirements and temperature changes, mix thoroughly, and allow an induction time of 10–15 min before application. 3. Before applying the next coat, ensure the sealer is hard dry, otherwise the effectiveness of sealing pinholes will be reduced. If the coating is to be applied over an old zinc dust primer film, chalk or zinc salts on the zinc dust coating shall be removed thoroughly. 4. If the coating chalks after long-term exposure, wash with high-pressure water or abrade the surface before applying the next coat. 5. When used to seal thermally sprayed metal, the metal layer shall be coated within the overcoating interval specified by the design specification. 6. During application and curing, the substrate temperature shall be above 5 °C and at least 3 °C above the dew point, and the relative humidity shall not exceed 85%. Temperature and relative humidity shall be measured on the substrate close to the work area. 7. Cutting structures coated with this coating produces fumes; appropriate protection shall be taken. 8. When work is interrupted, do not leave paint in hoses, spray guns or spray equipment. Flush all equipment thoroughly with thinner. If work is interrupted for too long, remix a fresh batch of paint before resuming. 9. All equipment shall be cleaned with thinner immediately after use. Periodically flushing spray equipment during the daily work is good practice. The frequency of cleaning depends on the quantity sprayed, temperature, spraying time and interruptions. 10. Remaining paint and empty cans shall be disposed of in accordance with relevant local regulations.

Packaging

17.7 kg per kitBase 13.3 kgCuring agent 4.4 kg
15 L per unitBase 10 LCuring agent 5 L

Storage

Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.

Safety Precautions

1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.

Scope of liability

The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery