Inorganic Zinc-rich Coating XH4007H is a zinc-rich primer. A two-component solvent-borne inorganic zinc silicate non-slip coating; its performance and composition comply with JT/T 722-2008. Parameters on this page: volume solids 65 ± 2%, dry film thickness 80/100/120 µm, theoretical spreading rate 5.4 m²/L.
Parameter source: T&H manufacturer's Technical Data Sheet (TDS) "Inorganic Zinc-rich Coating XH4007H"; spreading rate and other values are converted from the TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 65 ± 2% |
|---|---|
| Dry Film Thickness | 80/100/120 µm |
| Theoretical Spreading Rate | 5.4 m2/L |
| VOC | 400g/L |
| Density / Specific Gravity | 2.9 kg/L |
| Number of Components | Two-component |
| Flash Point | 17°C |
| Thinner | 5-15% |
| Mixing Ratio | Base : curing agent = 4.3:1 (by weight), 44:56 (by volume) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
A two-component solvent-borne inorganic zinc silicate non-slip coating; its performance and composition comply with JT/T 722-2008. For non-slip corrosion protection of bolted/riveted connection surfaces.
| Colour | Zinc grey |
|---|---|
| Gloss | N/A |
| density | 2.9 kg/L |
| Volume Solids | 65±2% |
| Volatile Organic Compounds | 400g/L |
| Flash Point | 17°C |
| Mixing ratio | Base : curing agent = 4.3:1 (by weight), 44:56 (by volume) |
| Typical dry film thickness | 80µm |
|---|---|
| Recommended dry film thickness | 80–120 µm, depending on system requirements |
| Induction time (20 °C) | No induction required |
| Thinner quantity (by volume) | Airless spray 5–20% | Air spray 5–20% | Roller or brush 5–15% |
| Recommended nozzle size | 0.43~0.64mm | 2.0~3.0mm | / |
| Recommended spray pressure | 15~20MPa | 0.3~0.6MPa | / |
| Application suitability | Recommended | Applicable | Suitable for small-area repair |
*For low-temperature application and where fast hard drying is required, use a fast thinner.
| Dry film thickness (µm) | 80 | 100 | 120 |
| Wet film thickness (µm) | 129 | 161 | 193 |
| Theoretical spreading rate (m²/L) | 8.1 | 6.5 | 5.4 |
Application data (typical 80 µm dry film, 65% relative humidity):
| Temperature | Surface Dry | Hard Dry | Pot Life | Recoat interval * | |
| Minimum | Maximum | ||||
| 5°C | 30min | 24h | 8h | / | |
| 15°C | 30min | 12h | 6h | / | |
| 25°C | 10min | 8h | 5h | / | |
| 40°C | 5min | 4h | 3h | / | |
*Normally this product requires no recoating
All surfaces to be coated shall be clean, dry and free from contaminants. Before coating, all surfaces shall be assessed and treated in accordance with ISO 8504:2000.
Blast to Sa 2½ with surface roughness 50–80 µm. Before rust removal, remove oil, grease and welding spatter, and grind welds and sharp corners. Film surfaces coated with this coating, where mechanically damaged and locally rusted, shall be locally blast cleaned to Sa 2½ or power-tool cleaned to St3 before local repair of the primer.
1. During application, ensure ventilation and exhaust, keep away from sources of ignition, and wear protective equipment such as masks and gloves; adequate ventilation shall also be maintained during curing. 2. Slowly add the zinc dust component while stirring the liquid component, power-stir until fully mixed, adjust the thinner quantity according to application needs and temperature changes, stir well, strain through a 120-mesh sieve before use, and keep stirring during use. If the zinc dust is poured directly into the liquid component, or thinner is added before mixing, the paint is difficult to mix uniformly, and defects such as gun blockage and uneven film tend to occur. 3. The maximum applied film thickness permitted for this product is 150 µm; over-thick application may cause cracking, affecting the curing process and adhesion. During application, pay attention to edge treatment and over-thick application, to avoid cracking and slow curing. 4. This product is suitable only for application over blast-cleaned steel surfaces and inorganic zinc silicate coating surfaces; it must not be applied over other types of coating. Substrate surfaces with too-low roughness or smooth coated surfaces cannot obtain good adhesion and may even shed. 5. During application and curing, the substrate temperature must be above 5 °C and at least 3 °C above the dew point, and relative humidity shall not exceed 85%. Temperature and relative humidity shall be measured on the substrate near the working area. Maintain good ventilation at the application site, with relative humidity not below 60%. If the humidity is below 60% during actual application, water spraying is required; when installing bolted/riveted members, assess the degree of cure per ASTM D4752, achieving at least Grade 4. 6. This product is not recommended for other applications. 7. Cutting structures coated with this coating produces fumes; take appropriate protection. 8. When work is interrupted, do not leave coating in the paint line, spray gun or spray equipment. Flush all equipment thoroughly with thinner. If the interruption is too long, it is recommended to mix a fresh batch of paint for application. 9. Clean all equipment with thinner immediately after use. Periodically flushing spray equipment during the working day is good practice. The flushing frequency depends on the spray quantity, temperature and spray duration, including interruptions. 10. Dispose of leftover paint and empty cans in accordance with the relevant local regulations.
| 25.4 kg per unit | Base 20.6 kg | Curing agent 4.8 kg |
| 8.8 L per unit | Base 3.8 L | Curing agent 5 L |
Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 9 months.
1. For the coating and its recommended thinners, see the safety sheets and the safety data of the relevant materials. This is a solvent-borne coating; avoid inhaling spray mist and solvent vapours, and avoid exposing skin and eyes and contact with uncured paint as far as possible. 2. All work related to the application and use of this product must comply with the relevant national health, safety and environmental standards and regulations. 3. If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation. 4. If in doubt about the suitability of this product, consult the company.
The information provided in this product data sheet is based on laboratory test results that we consider accurate, and is provided for application guidance only. All recommendations and advice given by T&H on the use of T&H products, whether in technical documents, special consultation or otherwise, are based on information we consider most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience, and it is for these end users to determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Therefore, T&H accepts no liability for any loss, injury or damage arising from the use of our products or from reliance on this product data sheet (unless otherwise agreed in writing). Data in this product data sheet may be revised as necessary based on practical experience and continued product development.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.