SteelPro FM119 Exterior Intumescent Fireproof Coating for Steel Structures belongs to Fire Protection. T&H Fire Shield Acrylic SteelPro FM119 is a solvent-borne fireproof coating composed of acrylic resin, high-quality chemical flame retardants, additives and solvents, certified to GB14907-2018, the standard for fireproof coatings for steel structures. The product with excellent fire performance is suitable for fire protection of steel structures such as steel columns, steel beams, supports, floors and steel corrugated sheets in civil steel structures, commercial buildings, TV towers, stadiums, airports, stations, large shopping malls and industrial plants. Parameters on this page: volume solids 76 ± 3%, dry film thickness 500/750/1000 µm, theoretical spreading rate 0.76 m2/L.
Parameter source: T&H manufacturer's Technical Data Sheet (TDS) "SteelPro FM119 Exterior Intumescent Steel Fire Protection"; spreading rate and other values are converted from the TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 76 ± 3% |
|---|---|
| Dry Film Thickness | 500/750/1000 µm |
| Theoretical Spreading Rate | 0.76 m2/L |
| VOC | 330g/L |
| Density / Specific Gravity | 1.35 ± 0.1 kg/L |
| Number of Components | One-component |
| Flash Point | 26°C |
| Thinner | XH9010 |
| Wet Film Thickness | 658/987/1316 µm |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
T&H Fire Shield Acrylic SteelPro FM119 is a solvent-borne fireproof coating composed of acrylic resin, high-quality chemical flame retardants, additives and solvents, certified to GB14907-2018, the standard for fireproof coatings for steel structures. The product with excellent fire performance is suitable for fire protection of steel structures such as steel columns, steel beams, supports, floors and steel corrugated sheets in civil steel structures, commercial buildings, TV towers, stadiums, airports, stations, large shopping malls and industrial plants.
the independent weather resistance of the fireproof coating can reach 12 months.
Colour: White
Gloss: not applicable
Density: 1.35±0.1 kg/L
Volume Solids: 76±3%
VOC: 330g/L
Flash Point 26 °C
Mixing ratio: single component
Pot life (25 °C): not applicable
| Areas of use | Fire resistance classification code | GB 14907-2018 corresponding report product model |
| Outdoor | Fp1.00 | GT-WRP-Fp1.00-FM119 |
| Outdoor | Fp1.50 | GT-WRP-Fp1.50-FM119 |
| Outdoor | Fp2.00 | GT-WRP-Fp2.00-FM119 |
| Outdoor | Fp2.50 | |
| Outdoor | Ft1.00 | GT-WRP-Ft1.00-FM119 |
| Outdoor | Ft1.50 | GT-WRP-Ft1.50-FM119 |
| Outdoor | Ft2.00 | GT-WRP-Ft2.00-FM119 |
Approval/compliance: CCCF certified by the Fire Product Compliance Assessment Centre of the Ministry of Emergency Management, in accordance with national standard
| Product tested and assessed per GB 14907-2018 steel structure fire protection coating requirements |
Typical DFT: 750µm Recommended DFT: According to different fire resistance requirements and fire protection standards of the project, XINHE New Materials Co., Ltd. will recommend the corresponding spray thickness. ※ For details, please consult XINHE New Materials Co., Ltd.
Application Methods: Airless Spray, Air Spray, Roller or Brush
| Thinner | XH9010 | / | XH9010 |
| Thinner quantity (by volume) | 0-15% | / | 5-15% |
| Recommended nozzle size | 0.43~0.58mm | / | |
| Recommended spray pressure | 15~20MPa | / | |
| Application suitability | Recommended | N/A | Applicable |
Theoretical spreading rate:
| Dry film thickness (µm) | 500 | 750 | 1000 |
| Wet film thickness (µm) | 658 | 987 | 1316 |
| Theoretical spreading rate (m²/L) | 1.52 | 1.01 | 0.76 |
Application Data (typical DFT 750µm):
| Temperature | Surface Dry | Dry to handle | Pot Life | Self-overcoating interval | |
| Minimum | Maximum* | ||||
| 5°C | 60min | 36h | / | 32h | / |
| 15°C | 40min | 15h | / | 13h | / |
| 25°C | 25min | 7h | / | 5.5h | / |
| 40°C | <10min | 4h | / | 4h | / |
The drying times listed in the above table are measured at a typical thickness of 750 µm under controlled temperature and relative humidity of 50%~75% with good ventilation.
*The maximum overcoating interval depends on the exposure environment and use of the coating, and normally shall not exceed 12 months.
8504:2000. If grease is present, clean with solvent according to SSPC-SP1.
cleaner to thoroughly remove grease, etc., and high-pressure clean water to remove salts and other contaminants. Steel must be coated with a primer approved by the company. Where conditions are limited, mechanical grinding to St3 is also acceptable; see the relevant requirements in the application guide.
guide.
1. The steel surface temperature during application of this product shall be 5~50 °C. The surface temperature must be at least 3 °C above the dew point, and the maximum relative humidity during application must not exceed 85%; ensure ventilation and exhaust during application, keep away from ignition sources, wear masks, gloves and other protective equipment, and maintain adequate ventilation during curing. 2. This product may be diluted as required, but excessive thinner will cause a risk of sagging; adjust the thinner amount according to temperature changes, mix thoroughly, and filter through a 120-mesh copper wire screen before use. Unused paint must be sealed when not used for a long period, otherwise skinning may occur. If skinning occurs, filter out the skin from the paint before use. 3. To ensure full performance of this product, it is important to achieve the specified dry film thickness. The dry film thickness of this product also depends on the shape and dimensions of the steel. Applicators must ensure that all areas of the steel reach the specified dry film range. Whether by airless spray or brush/roller, the fireproof coating must be applied in multiple coats to achieve the specified dry film thickness. For the first coat, dilute the fireproof coating to a film thickness of 0.25~0.35mm, and allow to dry for more than 6 h (20 °C, relative humidity 65%) before applying the next coat. It is recommended that the typical dry film thickness per spray coat is 750 µm (undiluted), and the maximum dry film thickness per roller coat is recommended to be 400 µm (undiluted). Applying higher film thickness may easily cause sagging and unacceptable solvent retention. 4. According to regulations, apply only over a primer approved by the company; please consult the company's technical representative regarding approved primers. This product is available only in white; depending on the purpose of the coating system, a coat of this product may be required
Compatible and approved topcoats; consult the company's technical representative regarding the selection of a topcoat for specific conditions. 5. This product has high viscosity and exhibits false body during storage. Stir briefly before application to mix uniformly and break the false body, ensuring good flow during application; excessive stirring may cause solvent evaporation. This product is thermoplastic and ductile; at temperatures above 40 °C, the film may show marks under mechanical action, and mechanical strength recovers when the temperature decreases. 6. When work is suspended, do not leave paint in the paint line, spray gun or spray equipment. Flush all equipment thoroughly with thinner. 7. All equipment shall be cleaned with thinner immediately after use. Periodic flushing of spray equipment during the daily work process is good practice. Cleaning frequency depends on spray volume, temperature, spray time, including interruption time and other factors. 8. Fire-retardant coatings shall not be exposed to rain during application and curing; handle with care. Before and during use, inhalation of paint mist must be avoided, skin and eye exposure shall be minimized, and contact with wet paint shall be avoided. Without a topcoat or intermediate waterproof layer, the fire-retardant coating has only limited water resistance. The fire-retardant coating may be moved outdoors for curing only after a topcoat or temporary waterproof layer has been applied. 9. Residual paint and empty containers shall be disposed of in accordance with applicable regional regulations.
20 kg/drum
Keep sealed in a ventilated, cool, dry place away from sources of ignition. Minimum 12 months.
1. For the paint and recommended thinner, refer to the safety data sheet and the safety data of the relevant materials. Although this is a water-borne paint, inhalation of paint mist must still be avoided, skin and eye exposure shall be minimized, and contact with wet paint shall be avoided. 2. All work related to the application and use of this product must be carried out in accordance with the relevant national health, safety and environmental standards and regulations. 3. Welding or flame cutting on metal coated with this product generates dust and fumes; suitable personal protective equipment and adequate local ventilation are therefore required. 4. If there is any doubt about the suitability of this product, consult the company.
The information provided in this product data sheet is based on laboratory test results we consider accurate and is intended for application guidance only. All opinions and recommendations of XINHE regarding the use of XINHE products, whether in technical documents, specific consultations or other forms, are based on information we consider most reliable. Our products and the information provided are intended for users with the requisite knowledge and industrial experience, and it is ultimately the end customers who shall determine whether these products are suitable for their use. XINHE cannot control the quality and condition of the substrate, nor the various factors affecting product use. Accordingly, XINHE assumes no liability for any loss, injury or damage arising from the use of its products or from reference to this product data sheet (unless otherwise agreed in writing). Data in the product data sheet will be revised as necessary based on practical experience and the need for continuous product development.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.