Water-borne Byaqua 5600 Thermal Insulation Coating

Quick Specs

Waterborne Yacote Thermal Insulation Coating Byaqua 5600 is a thermal insulation coating, in the waterborne coating system. A one-component waterborne liquid thermal insulation coating, resistant to temperatures up to 150 °C. Parameters on this page: volume solids 63 ± 3%, dry film thickness 500/800/1000 µm, theoretical spreading rate 0.63 m²/L.

Parameter source: T&H original technical data sheet (TDS) for Water-borne Yacote Thermal Insulation Coating Byaqua 5600; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids63 ± 3%
Dry Film Thickness500/800/1000 µm
Theoretical Spreading Rate0.63 m2/L
VOC35g/L
Density / Specific Gravity0.5-0.6 kg/L
Number of ComponentsOne-component
Thinner0-5%
Colour / AppearanceWhite and other colours
GlossMatt

Browse Similar Models by CategoryThis model belongs to: Thermal Insulation, Water-borne

FAQ

How many components is Waterborne Yacote Thermal Insulation Coating?
Waterborne Yacote Thermal Insulation Coating is a one-component product. After opening, stir thoroughly and it is ready for application; no on-site mixing is required.
What dry film thickness is typically applied for Waterborne Yacote Thermal Insulation Coating?
The typical dry film thickness of Waterborne Yacote Thermal Insulation Coating is 500/800/1000 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Waterborne Yacote Thermal Insulation Coating?
The theoretical spreading rate of Waterborne Yacote Thermal Insulation Coating is 0.63 m²/L; the practical quantity is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Waterborne Yacote Thermal Insulation Coating?
The volume solids of Waterborne Yacote Thermal Insulation Coating is 63 ± 3%.
What is the VOC of Waterborne Yacote Thermal Insulation Coating?
The VOC of Waterborne Yacote Thermal Insulation Coating is 35 g/L.
What is the gloss of Waterborne Yacote Thermal Insulation Coating?
The gloss of Waterborne Yacote Thermal Insulation Coating is matt.
What thinner is used for Waterborne Yacote Thermal Insulation Coating?
Recommended thinner for Waterborne Yacote Thermal Insulation Coating: 0-5%.
Where can Waterborne Yacote Thermal Insulation Coating be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Curing agent: none; thinner: water

Product Description

A one-component waterborne liquid thermal insulation coating, resistant to temperatures up to 150 °C. It can replace the traditional process of laying thermal insulation and an outer jacket, and is economical and practical. It is used to control and stabilise the operating temperature of storage tanks, tank containers and vessels. On complex structures, the insulation and energy-saving advantage of its integrated seamless bonding system is particularly evident. It is suitable only for non-immersed dry environments; avoid long-term standing water or water accumulation that does not drain away on the surface.

Product Characteristics

Basic physical and chemical data

ColourWhite and other colours
GlossMatt
density0.5-0.6 kg/L
Volume Solids63±3%
Volatile Organic Compounds35g/L

Application parameters

Typical dry film thickness1000µm
Recommended dry film thickness500~1000 µm, depending on system requirements

Application Methods

Thinner quantity (by volume)Airless spray /Architectural coating spray gun 0-5%Roller or brush 0–5%
Recommended nozzle size/2.0~6.0mm/
Recommended spray pressure/0.3~0.4MPa/
Application suitability/ApplicableSmall-area touch-up only

Theoretical Spreading Rate

Dry film thickness (µm)5008001000
Wet film thickness (µm)7941270171
Theoretical spreading rate (m²/L)1.260.790.63

Application data (typical dry film thickness 1000 µm)

TemperatureSurface DryHard DryPot LifeRecoat interval
MinimumMaximum*
20°C4h24h/24h/

*The maximum recoat interval depends on the exposure environment and the end use of the coating.

Surface Preparation

Previous CoatA suitable primer must be used, such as an epoxy primer or a silicone high-temperature primer; before application, keep

the surface dry and free from contamination. If the existing coating has failed, prepare to the substrate and coat in accordance with the complete coating system specification.

Precautions

1. During application, ensure ventilation and exhaust, keep away from sources of ignition, and wear protective equipment such as masks and gloves; adequate ventilation should also be maintained during curing. 2. When stirring, stir slowly and continuously until the paint is thoroughly mixed and reaches a completely homogeneous state. After correct and thorough mixing, the product in its completely homogeneous state should be a thick (high-viscosity) but smoothly flowing liquid, with little or no lumps or agglomerates. 3. The paint should be thoroughly mixed without thinner. Any thinning must be carried out only after the paint is completely mixed, after checking the state of the mixture. If dilution is genuinely necessary on site, only a small amount of tap water may be added at a time. 4. The ambient temperature should be controlled at 5-35 °C, and the relative humidity must not exceed 75%. If conditions permit, indoor application is preferred, as it better ensures the appearance quality. 5. A single coat can achieve a film thickness of 500 µm to 1000 µm; multiple coats can be applied as required, and a 4-coat system can achieve a film thickness of 4000 µm. 6. A suitable primer and topcoat must be used; subsequent coats may be acrylic topcoat, polyurethane topcoat, fluorocarbon topcoat, etc. 7. Cutting structures coated with this product produces smoke and dust; take appropriate protection. 8. When work is interrupted, do not leave the coating in hoses, spray guns or spray equipment. Flush all equipment thoroughly with thinner. If the interruption is too long, mix a fresh batch of paint for application. 9. All equipment should be cleaned with thinner immediately after use. Periodic flushing of spray equipment during the working day is good practice. The cleaning frequency depends on spray volume, temperature, spray time and factors including interruptions. 10. Surplus paint and empty containers must be disposed of in accordance with the relevant regional regulations.

Packaging

3.5L5L

Storage

Keep sealed and store in a ventilated, cool, dry place away from sources of ignition; the ideal storage temperature is 5-35 °C. Minimum 12 months

Safety Precautions

1. For the coating and recommended thinner, see the safety data sheet and safety data of the related materials; inhalation of spray mist and solvent must be avoided, exposure of skin and eyes should be minimised, and contact with wet paint avoided. 2. All work involving the application and use of this product must be carried out in accordance with all relevant national health, safety and environmental standards and regulations. 3. Welding or flame cutting on metal coated with this product will produce dust and fumes; suitable personal protective equipment and adequate local exhaust ventilation are therefore required. 4. If in doubt about the suitability of this product, consult the Company.

Scope of liability

The information in this data sheet is based on laboratory test results which we believe to be accurate, and is provided for application guidance only. All opinions and suggestions regarding the use of T&H products, whether in technical documents, special enquiries or otherwise, are based on information which we believe to be the most reliable. Our products and the information provided are intended for users with the necessary knowledge and industrial experience; it is ultimately these end customers who determine whether the products are suitable for their use. T&H cannot control the quality and condition of the substrate, nor the various factors affecting the use of the product. Accordingly, T&H accepts no liability for any loss, injury or damage arising from the use of the company's products or from reference to this data sheet (except as otherwise provided in a separate written agreement). The data sheet data are subject to necessary modification based on practical experience and the need for continuous product development.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery