China-based coatings exporter — industrial & marine protective coatings from China's production bases

HI-ALKYD 1041 Fast-drying Alkyd Primer

Quick Specs

HI-ALKYD 1041 Fast-drying Alkyd Primer is an alkyd coating used as a primer. Used for protective coating of steel structure surfaces such as bridges, petrochemical, power, steel structures, pipelines, equipment and steel frames in normal environments. HI-ALKYD 1041 Fast-drying Alkyd Primer is a fast-drying, one-component anti-rust primer based on alkyd resin. 1.48 kg/L (slight variation with colour). 393 g/L. The surface to be coated should be clean, dry and uncontaminated. Parameters on this page: volume solids 68 ± 2%; dry film thickness 30–60 µm; theoretical spreading rate 0.11 kg/m².

Source: NIPPON INDUSTRIAL original technical data sheet (TDS) 'HI-ALKYD 1041 Fast-drying Alkyd Primer'. Spreading rate and other values converted from the TDS; for reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids68 ± 2%
Dry Film Thickness30-60µm
Theoretical Spreading Rate0.11 kg/m²
VOC393 g/L. The surface to be coated should be clean, dry and uncontaminated. Surface assessment and preparation should follow IS…
Density / Specific Gravity1.48 kg/L (varies slightly with colour)
Number of ComponentsOne-component
ThinnerThinner 0920
Mixing RatioThis product is single-component; no mixing is required
Colour / AppearanceBrown-red/grey

Browse Similar Models by CategoryThis model belongs to: Primer, Alkyd

FAQ

How many components does HI-ALKYD 1041 contain?
HI-ALKYD 1041 is a one-component product. Stir thoroughly before use; no on-site mixing is required.
What is the mixing ratio of HI-ALKYD 1041?
Mixing ratio of HI-ALKYD 1041: this is a one-component product, no mixing required.
What is the typical dry film thickness of HI-ALKYD 1041?
Typical dry film thickness of HI-ALKYD 1041: 30–60 µm; final value depends on the coating system and design requirements.
What is the theoretical spreading rate of HI-ALKYD 1041?
Theoretical spreading rate of HI-ALKYD 1041: 0.11 kg/m²; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of HI-ALKYD 1041?
Volume solids of HI-ALKYD 1041: 68 ± 2%.
What is the VOC of HI-ALKYD 1041?
VOC of HI-ALKYD 1041: 393 g/L. The surface to be coated should be clean, dry and uncontaminated. Surface assessment and preparation should follow IS….
Which thinner is recommended for HI-ALKYD 1041?
Recommended thinner for HI-ALKYD 1041: Thinner 0920.
Which standards apply to HI-ALKYD 1041?
As recorded in the technical data on this page: surface assessment and cleaning shall refer to ISO8504; blasting: blast clean to grade Sa2 (ISO 8501-1:2007) or SSPC-SP6 (or SSPC-SP10 for better results). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can HI-ALKYD 1041 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product description

HI-ALKYD 1041 Fast-drying Alkyd Primer is a fast-drying, one-component anti-rust primer based on alkyd resin. The product dries quickly, with good anti-rust and application performance.

Product use

Used for protective coating of steel structure surfaces such as bridges, petrochemical, power, steel structures, pipelines, equipment and steel frames in normal environments

Physical properties

ColourBrown-red/grey
Solids content (by volume)68±2%
Density1.48 kg/L (varies slightly with colour)
VOC393 g/L. The surface to be coated should be clean, dry and uncontaminated. Surface assessment and preparation should follow ISO 8504. Oil and

Surface Preparation

Remove oil and grease in accordance with SSPC-SP1 solvent cleaning.

Blast cleaning to Sa2 (ISO 8501-1:2007) or SSPC-SP6 (or SSPC-SP10 for better results). If the blasted surface oxidises before coating, it shall be re-prepared to the specified standard. Surface defects exposed after blasting shall be treated by grinding, filling or other suitable methods. The surface profile shall be 40–75 µm.

Repair of damaged areas: damaged areas must be blast-cleaned to Sa 2½ (ISO 8501-1:2007) or SSPC-SP6 (blast-clean to SSPC-SP10 for optimum performance). If local areas cannot be blasted, power tool cleaning to St 3 (ISO 8501-1:2007) is allowed. Only after surface preparation can the primer be applied. Before applying HI-ALKYD 1041 Fast-drying Alkyd Primer, ensure the surface to be coated is clean and dry, and apply within the specified recoat interval (refer to the relevant product instructions).

Other surfaces: if the coating is to be applied to other substrates, consult the Protective Coatings Division of Nippon Paint Industrial Coatings.

Application is not recommended when the ambient temperature is below 5 °C or above 50 °C, or relative humidity exceeds 85%; steel

Application conditions

The temperature should be at least 3 °C above the dew point of the surrounding air.

Application guidance

Mixing ratioThis product is single-component; no mixing is required
Theoretical spreading rate0.11 kg/m² (at 50 µm dry film)
ThinnerThinner 0920: the amount of thinning shall not exceed the range permitted by local regulations.

Application method

Roller/brush/air spray: suitable for pre-coating and small-area application. Air-assisted airless spray: suitable for large-area application. Whichever method is used, the specified dry film thickness must be achieved.

Application parameters

Air SprayNozzle size: 1–2 mm; air pressure: 0.3–0.5 MPa
Airless SprayTip size: 0.017"–0.021"; nozzle pressure: 120–150 kg/cm²
Typical film thickness30–60 µm DFT : 73–146 µm WFT — drying time
Substrate Temperature15°C25°C40°C
Touch dry time60min30min20min
Hard dry time2h1h0.6h
Fully cured14d7d
Minimum recoat time2h1h0.6h
Maximum recoat time*-

Note: the surface should be free of chalking and contamination before recoating. When the film has been exposed outdoors too long, or the surface is smooth or contaminated, recoat adhesion is adversely affected, so the surface must be roughened, sweep-blasted or high-pressure water jetted to ensure adequate adhesion.

The data above are for guidance only. Actual recoat and drying times may be shorter or longer depending on film thickness, ventilation, humidity, coating system, and prior hand or mechanical preparation conditions.

The following primers/topcoats are recommended for use with HI-ALKYD 1041 Fast-drying Alkyd Primer

Recommended system

Topcoat

Select the coating system according to the specific requirements; refer to the product manual or contact Nippon Paint for professional guidance.

Packaging: set, weight 25 kg, pack size 18 L. Storage: shelf life (from production date): 12 months (at 25 °C). Store in a cool, dry, ventilated warehouse meeting fire safety requirements, with warehouse temperature not exceeding 40 °C. 12 months at 25 °C from the production date. The above is the minimum shelf life; inspect before continued use thereafter.

Due to the nature of alkyd products, skinning tends to occur after long-term storage. If skinning occurs, simply remove the skin; the product can still be used normally.

Safety precautions

Safety information.

All information in this product data sheet is based on laboratory tests and practical experience. However, since the product is subject to many unforeseeable and uncontrollable factors in actual use, we guarantee only the quality of the product itself. Read this data sheet carefully and confirm with Nippon Paint that it is the latest version before using the product.

We reserve the right to modify this product data sheet without prior notice.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery