← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Tankguard Type II Solvent-free Phenolic Epoxy Coating Type II

Quick Specs

Tankguard Type II Solvent-free Phenolic Epoxy Coating Type II belongs to epoxy coatings. Industrial protective coatings segment: specifically designed to meet the critical requirements of the oil industry and others. This is a ceramic filler-reinforced two-component solvent-free amine-cured phenolic epoxy coating. Parameters on this page: volume solids 100%, dry film thickness 150–500 µm, theoretical spreading rate 6.7–2 m²/L. Comparable products of the same brand and type: Jotapipe IL 425 Phenolic Epoxy 425 for aviation fuel pipelines, Jotapipe IL 426 Phenolic Epoxy 426 for sour crude oil pipelines, Tankguard NCV N Phenolic Epoxy Static Conductive Coating.

Parameter source: JOTUN original Technical Data Sheet (TDS) 'Tankguard Type II Solvent-free Phenolic Epoxy Coating Type II'; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids100%
Dry Film Thickness150–500 µm
Theoretical Spreading Rate6.7–2 m²/L
VOC48 g/L (US)
Density / Specific Gravity1.4 kg/L
Number of ComponentsTwo-component
Flash Point100 °C
Mixing Ratio3 parts : 1 part (by volume)
GlossGloss (70–85)

Browse Similar Models by CategoryThis model belongs to: Epoxy, Phenolic

FAQ

How many components does Tankguard Type II have?
Tankguard Type II is a two-component product. Mix according to the mixing ratio in the 'Application Data' table on this page before use.
What is the mixing ratio of Tankguard Type II?
The mixing ratio of Tankguard Type II is 3 parts : 1 part (by volume).
What dry film thickness is typically applied for Tankguard Type II?
The conventional dry film thickness of Tankguard Type II is 150–500 µm, determined specifically by the coating system and design requirements.
What is the theoretical spreading rate of Tankguard Type II?
The theoretical spreading rate of Tankguard Type II is 6.7–2 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Tankguard Type II?
The volume solids of Tankguard Type II is 100%.
What is the VOC of Tankguard Type II?
The VOC of Tankguard Type II is 48 g/L (US).
What is the gloss of Tankguard Type II?
The gloss of Tankguard Type II is Glossy (70–85).
What is the flash point of Tankguard Type II?
The flash point of Tankguard Type II is 100 °C. Storage, transport and application shall be carried out in accordance with the product Safety Data Sheet.
How long does Tankguard Type II take to dry?
Drying time of Tankguard Type II under standard conditions: touch dry 15 h; actual drying is affected by temperature, film thickness and ventilation.
Which standards does Tankguard Type II involve?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Tankguard Type II be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Tankguard Type II

Product description

This is a two-component, solvent-free, amine-cured phenolic epoxy coating reinforced with ceramic fillers. It is highly resistant to most sour crude oils, many chemicals and solvents. It can be used as a primer, intermediate coat or topcoat in atmospheric and immersion environments. Suitable for properly prepared carbon steel substrates.

Typical Use

Industrial protective coatings:

Designed to meet the critical requirements of the oil industry. Other

Approvals and Certificates

Petrobras N-2912 specification for Type II phenolic epoxy coatings. Other certificates and approvals are available upon request.

Colour

Munsell 5G8/4, Munsell N6.5, Munsell N9.5

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 3233100%
Gloss (GU 60°)ISO 2813Gloss (70–85)
Flash PointISO 3679 Method 1100 °C
DensityTheoretical Value1.4 kg/L
RegionRegulationsTest / StandardVOC Value
USCARB(SCM)2020 / SCAQMD rule 1113Calculation48 g/L

The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness150–500 µm
Wet Film Thickness
Theoretical Spreading Rate6.7–2 m²/L

Surface Preparation

NoteWater jetting is for maintenance only. For new construction, water jetting is permitted only in combination with abrasive blasting.

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSa 2½ (ISO 8501-1)
Coated surfaceA clean, dry and sound compatible primer.

The recommended surface preparation provides optimum properties including adhesion, corrosion resistance, heat resistance and chemical resistance.

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by airless spray.
Brush:Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness.

The temperature of both components is recommended to be between 23–28 °C before commencing application.

Mixing Ratio (by Volume)

Solvent-Free Phenolic Epoxy Coating Type II, Component A3 parts
Solvent-Free Phenolic Epoxy Coating Type II, Component B1 part

Thinner / Cleaning Solvent

CleanerJOTUN Thinner No. 17

When the thinner is used as a cleaning solvent, it must first comply with local regulatory requirements

In China, the cleaning solvent must comply with GB 38508-2020

Airless Spray Guidance

Nozzle tip size (inch/1000):19-25
Nozzle pressure (minimum):175 bar/2500 psi

Due to the short pot life after mixing, it is particularly important to thoroughly clean the nozzle and other parts of the spray equipment promptly after completion.

Drying and Curing Time

Substrate Temperature10 °C23 °C40 °C
Touch Dry15 h6 h1.5 h
Walk-on Dry30 h12 h4 h
Minimum recoat interval30 h12 h4 h
Dry/cured to service15 days7 days4 days

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature23 °C
Induction Time10 min
Pot Life45 min
Induction time and pot life are reduced at higher temperatures

Heat Resistance

Temperature

Drying, atmosphericContinuous 140 °CPeak -
Immersed, sea water70 °C-
Immersed, crude oil80 °C90 °C

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous coat:itself
Subsequent coat:itself

Typical Packaging Sizes

VolumeContainer Size
(L)
Solvent-Free Phenolic Epoxy Coating Type II, Component A1520
Solvent-Free Phenolic Epoxy Coating Type II, Component B5

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Solvent-Free Phenolic Epoxy Coating Type II, Component A12 months
Solvent-Free Phenolic Epoxy Coating Type II, Component B12 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating, phenolic coating

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery