← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Tankguard Storage HS High-solids Phenolic Epoxy Tank Coating

Quick Specs

Tankguard Storage HS High-solids Phenolic Epoxy Tank Coating is an epoxy coating. Industrial protective coatings segment: dedicated as a lining coating for offshore, onshore and underground tanks and pipelines, such as chemical storage, wastewater, grey water, industrial water pipelines, concrete bunds, fire water lines and drilling mud tanks. Can be used as primer, intermediate coat or topcoat in atmospheric and immersion environments. Parameters on this page: volume solids 72 ± 2%, dry film thickness 100–200 µm, theoretical spreading rate 7.2–3.6 m²/L.

Parameter source: JOTUN manufacturer's Technical Data Sheet (TDS) "Tankguard Storage HS High-solids Phenolic Epoxy Tank Coating"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids72 ± 2%
Dry Film Thickness100–200 µm
Theoretical Spreading Rate7.2–3.6 m²/L
VOC243 g/L (China)
Density / Specific Gravity1.5 kg/L
Number of ComponentsTwo-component
Flash Point34 °C
ThinnerJotun Thinner No. 17 / JOTUN Thinner No. 23
Mixing Ratio3 parts : 1 part (by volume)

Browse Similar Models by CategoryThis model belongs to: Epoxy, Phenolic

FAQ

How many components does Tankguard Storage HS have?
Tankguard Storage HS is a two-component product. Mix at the ratio given in the Application Data table on this page before use.
What is the mixing ratio of Tankguard Storage HS?
The mixing ratio of Tankguard Storage HS is 3 parts : 1 part (by volume).
What dry film thickness is normally applied for Tankguard Storage HS?
The normal dry film thickness of Tankguard Storage HS is 100–200 µm, determined by the coating system and design requirements.
What is the theoretical spreading rate of Tankguard Storage HS?
The theoretical spreading rate of Tankguard Storage HS is 7.2–3.6 m²/L; actual consumption is adjusted for substrate roughness, application loss and colour hiding power.
What is the volume solids of Tankguard Storage HS?
The volume solids of Tankguard Storage HS are 72 ± 2%.
What is the VOC of Tankguard Storage HS?
The VOC of Tankguard Storage HS is 243 g/L (China).
Which thinner is used with Tankguard Storage HS?
Recommended thinner for Tankguard Storage HS: Jotun Thinner No. 17 / JOTUN Thinner No. 23.
What is the flash point of Tankguard Storage HS?
The flash point of Tankguard Storage HS is 34°C; storage, transport and application follow the product Safety Data Sheet.
How long does Tankguard Storage HS take to dry?
Drying time of Tankguard Storage HS under standard conditions: Touch Dry 12 h; actual results are affected by temperature, film thickness and ventilation.
Which standards apply to Tankguard Storage HS?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Tankguard Storage HS be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Tankguard Storage HS

Product description

This is a two-component amine-cured phenolic epoxy coating. Specially designed cargo tank/storage tank lining coating with excellent chemical resistance. Can be used as primer, intermediate coat or topcoat in atmospheric and immersion environments. Suitable for properly prepared carbon steel, galvanized steel, stainless steel and concrete substrates.

Typical Use

Industrial protective coatings:

Designed as a lining for offshore, onshore and underground tanks and pipelines, such as chemical storage, waste water, grey water, industrial water pipelines, concrete bunds, fire-fighting water lines and drilling mud tanks. May be used for pressure vessels. The coating has good resistance to high-temperature products. Refer to the industrial protective coatings corrosion resistance table.

Others

Approvals and Certificates

Certified according to IMO Res.288(87) and suitable for the PSPC standard for crude oil tanks. Other certificates and approvals are available on request.

Colour

Light grey, light red, red

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323372± 2 %
Gloss (GU 60°)ISO 2813Semi-gloss (35–70)
Flash PointISO 3679 Method 134 °C
DensityTheoretical Value1.5 kg/L
RegionRegulationsTest / StandardVOC Value
ChinaMandatory national standard of ChinaGB 30981.2-2025243 g/L
Coating hazards GB30981.2-S-Pb≤1000-NC

Contains reactive thinner

The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness100–200 µm
Wet Film Thickness140–280 µm
Theoretical Spreading Rate7.2–3.6 m²/L

Surface Preparation

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSa 2½ (ISO 8501-1)
Coated surfaceA clean, dry and sound compatible primer.
Stainless steelThe surface should be blasted with a non-metallic abrasive,“Blast clean using an approved non-metallic abrasive
hand- or machine-sanded using abrasive paper or fibre discs,to produce a sharp angular surface profile.”

to produce scratch marks on the surface.

Galvanised steelThe surface should be clean, dry and have a suitable profileSweep blast with a non-metallic abrasive to produce a clean,
°a rough and uniform surface.
ConcreteDry abrasive blast clean to SSPC-SP 13 / NACE No. 6.

The recommended surface preparation provides optimum properties including adhesion, corrosion resistance, heat resistance and chemical resistance.

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by airless spray.
Brush:Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness.
Roller:Roller application may be used only in areas such as drain holes, rat holes and small pipes.

Mixing Ratio (by Volume)

Tankguard Storage HS Comp A — High-Solids Phenolic Epoxy Tank Coating, Component A3 parts
Tankguard Storage HS Comp B — High-Solids Phenolic Epoxy Tank Coating, Component B1 part

Thinner / Cleaning Solvent

ThinnerJotun Thinner No. 17 / JOTUN Thinner No. 23

Airless Spray Guidance

Nozzle tip size (inch/1000):17-21
Nozzle pressure (minimum):150 bar/2100 psi

Drying and Curing Time

Substrate Temperature-5 °C0 °C5 °C10 °C15 °C23 °C40 °C
Touch Dry12 h10 h5 h4 h3 h2 h1 h
Walk-on Dry48 h30 h16 h12 h10 h8 h4 h
Minimum recoat interval24 h20 h10 h8 h6 h4 h2 h
Dry/cured to service30 days21 days14 days10 days8 days6 days3 days

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.

At application temperatures of 23 °C and above, tanks for crude oil and clean petroleum products may be returned to service 48 hours after application of the final coat.

For the resistance list including clean petroleum products, refer to the JOTUN product resistance guide.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature10 °C23 °C
Induction Time5 min
Pot Life2 h1.5 h

Heat Resistance

Temperature

Drying, atmosphericContinuous 200 °CPeak -
Immersed, sea water70 °C-
Immersed, crude oil120 °C-

For more detailed resistance information, see the Industrial Protective Products Resistance List on the JOTUN website, or contact your local JOTUN office.

Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous coat:Phenolic epoxy
Subsequent coat:Phenolic epoxy

Tankguard Holding Primer can be used for short-term protection and is fully compatible with the tank coating system.

Typical Packaging Sizes

VolumeContainer Size
(L)
Tankguard Storage HS Comp A — High-Solids Phenolic Epoxy Tank Coating, Component A1520
Tankguard Storage HS Comp B — High-Solids Phenolic Epoxy Tank Coating, Component B5

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Tankguard Storage HS Comp A — High-Solids Phenolic Epoxy Tank Coating, Component A24 months
Tankguard Storage HS Comp B — High-Solids Phenolic Epoxy Tank Coating, Component B24 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating, phenolic coating

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery