SteelMaster 1200HPE Exterior Intumescent Fire Protection Coating for Steel Structures 1200HPE is a fire protection coating. Suitable for steel structures exposed to exterior atmospheric environments; suitable for corrosion environment classes up to C5 with or without a topcoat. Can be applied directly to metal surfaces and used as an intermediate coat or topcoat in atmospheric environments. Parameters on this page: volume solids 99.5 ± 0.5%; number of components: two-component. Similar models from the same brand for comparison: Jotachar 1709 XT Epoxy Intumescent Coating, Jotachar 1709 Exterior Intumescent Fire Protection Coating for Steel Structures, Jotachar JF750 XT Epoxy Intumescent Coating.
Parameter source: JOTUN original technical data sheet (TDS) 'SteelMaster 1200HPE Exterior Intumescent Fire Protection Coating for Steel Structures 1200HPE'; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 99.5 ± 0.5% |
|---|---|
| Dry Film Thickness | — |
| Theoretical Spreading Rate | — |
| VOC | GB/T 34682-2017 8.3 9 g/L (China) |
| Density / Specific Gravity | — |
| Number of Components | Two-component |
| Flash Point | 100 °C |
| Thinner | Jotun Thinner No. 17 |
| Mixing Ratio | 2.35 parts : 1 part (by volume) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
SteelMaster 1200HPE
This is a two-component, solvent-free, amine-cured epoxy intumescent coating. Independently certified for fire protection of structural steel exposed to cellulosic fires. Can be applied directly to metal surfaces and used as an intermediate coat or topcoat in atmospheric environments. Suitable as an approved primer on carbon steel and hot-dip galvanized steel substrates.
Reactive fire protection coating specially developed for fire protection of steel structures. Suitable for steel structures exposed to exterior atmospheric environments; suitable for corrosion environment classes up to C5 with or without a topcoat.
When long-term appearance or colour requirements apply, a compatible topcoat is recommended. Contact the local JOTUN representative for detailed application procedure documents.
Others
BS 476 Part 20/21: Certifre certification, No. CF5857 (fire resistance duration up to 180 min)
Suitable for open beams (RT1356)
Tested and assessed based on EN 13381-8 and EN13381-10 (fire resistance duration up to 180 min).
Product with CE marking and European Technical Assessment ETA-21/1019; certified to ANSI/UL263 (ASTM E119) and CAN/ULC-S101; Chinese GB14907:2018; Australia AS 4100; VKF/AEAI Certificate No.: 33502
| Fire resistance | Class B-s1, d0 (EN 13501-1) |
|---|
ASTM E84: Class A
| Durability and service suitability | Z2, Z1, Y and X (EAD 350402-00-1106) |
|---|
Approved for UL 263 exterior environmental use; approved for UL 2431 classification Class I-A. Other certificates and approvals available upon request.
After Components A and B are fully mixed, a uniform light grey appearance is obtained.
| Property | Test / Standard | Description |
| Volume Solids | ISO 3233 | 99.5± 0.5% |
| Flash Point | ISO 3679 Method 1 | 100 °C |
| Region | Regulations | Test / Standard | VOC Value |
| US | CARB(SCM)2020 / SCAQMD rule 1113 | Calculation | 15 g/L |
| Hong Kong | Air Pollution Control (VOC) Regulation | Calculation | 15 g/L |
| EU | European Paint Directive 2004/42/CE | ISO 11890-2 | 20 g/L |
| China | GB 30981-2020 Limit of harmful substances of industrial protective coatings | GB/T 34682-2017 8.3 9 g/L |
The data listed are based on factory batch production and may vary slightly with colour.
Typical recommended specification range
Dry film thickness:
0.5 mm to 4 mm per coat.
All steelwork must be coated at the correct film thickness to achieve the required fire rating. Refer to the current thickness tables. For details, consult your local JOTUN office.
Recommended: use a two-component spray pump to control typical application thickness at 3 to 4 mm; this range achieves an ideal balance among film formation quality, surface finish and thickness control. In actual application, WFT may be appropriately increased according to operating conditions such as steel structure configuration, geometry, application environment parameters, pump model, operator proficiency, application accessibility and primer type. Subsequent coats may be applied after the material is fully cured, generally recommended 60 min after application; the specific time shall be adjusted according to on-site temperature, humidity and other environmental parameters.
Maximum WFT is the highest film thickness at which the coating system can be applied without sagging. If a thicker coat is applied, sagging may occur, and recoating intervals, drying and handling times will be prolonged.
When spraying with a single-component pump, dilution is required. WFT can reach 1.5 mm, depending on the amount of thinner added, pump type, pump settings, spray technique and other factors.
Refer to the application guide for more detailed information.
Maximum permitted dry film thickness (BS and EN certificates)
Where measured thickness exceeds the limit, the measured thickness must be reduced by suitable means, based on the maximum thickness permitted by the profile and layout of the specific section.
I/H beam, 3 sides: 9.02 mm; I/H beam, 4 sides: 9.02 mm; I/H column, 4 sides: 11.06 mm; CHS & RHS column: 13.77 mm
For further information, see the Application Guide.
Surface Preparation
| Substrate | Minimum | Recommended |
| Coated surface | A clean, dry and sound compatible primer. | |
| Carbon Steel | Power tool cleaning to St3, with a defined roughness profile. | Sa 2½ (ISO 8501-1) |
This product may be applied by the following methods
| Spray: | Use two-component spray equipment with heating function. A single-component airless spray pump may also be used. For more information, refer to the application guide. |
| Brush: | For repair or edge finishing of small areas. |
| SteelMaster 1200HPE Comp A Exterior Intumescent Steel Fire Protection 1200 HPE, Component A | 2.35 parts |
| SteelMaster 1200HPE Comp B Exterior Intumescent Steel Fire Protection 1200 HPE, Component B | 1 part |
Before use, each component shall be pre-conditioned at 20–30°C. Stir or mix thoroughly with a power mixer before application.
| Thinner: | Jotun Thinner No. 7 | /Jotun Thinner No. 17 |
| JOTUN Thinner No. 7 | JOTUN Thinner No. 17 / JOTUN Thinner No. 10 | |
| Maximum thinning: | 4 % |
When two-component spray or brush application is used, no additional dilution is required. For single-component airless spray pumps with a hopper, the dilution ratio is usually 1%–3% of total volume; the recommended maximum dilution ratio is 4%.
Depending on pump type and environmental conditions, dilution may not be required, for example when using a spray pump with hydraulic piston and follower plate in warm climates. Dilution affects sag resistance and delays drying time.
| Cleaner | Jotun Thinner No. 7 JOTUN Thinner No. 7 or Jotun Thinner No. 17 JOTUN Thinner No. 17 |
|---|
When the thinner is used as a cleaning solvent, it must first comply with local regulatory requirements
| Nozzle Tip Size (inch/1000) | 23-27 |
|---|
| Substrate Temperature | 10 °C | 15 °C | 23 °C | 40 °C |
| Touch Dry | 14 h | 12 h | 8 h | 3 h |
| Handle dry | 30 h | 16 h | 8 h | |
| Minimum recoat interval | 8 h | 6 h | 4 h | |
| Dry/cured to service | 30 h | 24 h | 16 h | |
For the maximum recoat interval, refer to the Application Guide (AG) for this product.
The minimum drying recoat interval is for self-recoating. See the additional guidance for the finish coat.
All drying times are measured at a WFT of 4000 µm, under controlled temperature and relative humidity below 85%.
Topcoat:
The minimum overcoating interval before topcoat application is 16 h. The coating shall reach handle dry and shall not show marks on the surface when DFT is measured with a DFT gauge. Before topcoat application, the application contractor must ensure the dry film has reached the specified DFT.
Minimum product application temperature down to 5°C (41°F). For improved application performance and drying, steel and air temperature should be above 10°C.
| Touch Dry | The state at which light finger pressure leaves no mark or stickiness. |
|---|---|
| Handle dry | The minimum time after application before handling will not damage the film. |
Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.
Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.
| Paint temperature | 15 °C | 23 °C | 40 °C |
| Pot Life | 45 min | 40 min | 25 min |
Pot life does not apply to two-component spray equipment. For single-feed airless spray, the mixed paint shall be used as soon as possible. Due to the exothermic reaction, the larger the quantity of paint mixed, the shorter the pot life.
Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.
| Previous coat: | Epoxy, zinc phosphate epoxy, modified epoxy, zinc-containing epoxy |
| Subsequent coat: | Acrylic, acrylic polyurethane topcoat, polysiloxane |
Primers and topcoats used in systems with this product shall be approved by JOTUN. Consult JOTUN for the latest list of approved primers.
| Volume | Container Size | |
| (L) | ||
| SteelMaster 1200HPE Comp A Exterior Intumescent Steel Fire Protection 1200 HPE, Component A | 11.2 / 17.6 | 20 / 20 |
| SteelMaster 1200HPE Comp B Exterior Intumescent Steel Fire Protection 1200 HPE, Component B | 4.8 / 14.9 | 10 / 20 |
Packaging sizes:
Small pack 16 L – Component A (11.2 L) + Component B (4.8 L)
Medium pack 50 L – 2 parts Component A (17.6 L) + Component B (14.9 L)
Large pack 520 L – 2 parts Component A (182.4 L) + Component B (155.2 L) (manufactured to order)
For further information, contact your local JOTUN sales representative.
The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.
Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
| Storage temperature | 5°C – 35°C. Avoid direct sunlight during storage. Protect from frost. |
|---|
| SteelMaster 1200HPE Comp A Exterior Intumescent Steel Fire Protection 1200 HPE, Component A | 18 months |
| SteelMaster 1200HPE Comp B Exterior Intumescent Steel Fire Protection 1200 HPE, Component B | 18 months |
For 200 L drum packaging, the shelf life of Component A is 9 months and that of Component B is 6 months.
A mechanical agitator is recommended for large packs.
In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.
This product can contribute to green building standard credits. Visit Jotun.com for more information or contact your local JOTUN representative.
EPDs are available at www.epd-norge.no
For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.
Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.
When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.
Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.
The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.
Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.
In case of any discrepancy between language versions, the English (UK) version shall prevail.
Data is subject to the manufacturer's latest version; in all cases the manufacturer's latest TDS prevails.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.