← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Resist 60 Inorganic Zinc Silicate Primer 5DG

Quick Specs

Resist 60 Inorganic Zinc Silicate Zinc-rich Primer 5DG is a zinc-rich primer. Recommended for offshore environments, refineries, power stations, bridges, buildings and mining equipment. The zinc dust in this product complies with ASTM D520, Type II. Parameters on this page: volume solids 60 ± 2%, dry film thickness 50–90 µm, theoretical spreading rate 12–6.7 m²/L. Comparable products of the same brand and type: Resist 65 Inorganic Zinc Silicate Zinc-rich Primer, Resist 78 KV Inorganic Zinc Silicate Zinc-rich Primer, Resist 78 Inorganic Zinc Silicate Zinc-rich Primer.

Parameter source: JOTUN original technical data sheet (TDS) "Resist 60 Inorganic Zinc Silicate Zinc-rich Primer 5DG"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids60 ± 2%
Dry Film Thickness50–90 µm
Theoretical Spreading Rate12–6.7 m²/L
VOC456 g/L (US)
Density / Specific Gravity2 kg/L
Number of ComponentsTwo-component
Flash Point16 °C
ThinnerTo accelerate evaporation
Mixing Ratio7 parts : 1 part (by volume)

Browse Similar Models by CategoryThis model belongs to: Primer, Zinc-rich Primer

FAQ

How many components does Resist 60 have?
Resist 60 is a two-component product; mix according to the mixing ratio in the "Application Data" table on this page before use.
What is the mixing ratio of Resist 60?
The mixing ratio of Resist 60 is 7 parts : 1 part (by volume).
What dry film thickness is typically applied for Resist 60?
The conventional dry film thickness of Resist 60 is 50–90 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Resist 60?
The theoretical spreading rate of Resist 60 is 12–6.7 m²/L; the actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Resist 60?
The volume solids of Resist 60 are 60 ± 2%.
What is the VOC of Resist 60?
The VOC of Resist 60 is 456 g/L (US).
What thinner is used for Resist 60?
Recommended thinner for Resist 60: to accelerate evaporation.
What is the flash point of Resist 60?
The flash point of Resist 60 is 16 °C; storage, transport and application shall be carried out in accordance with the product safety data sheet.
How long does Resist 60 take to dry?
Drying time of Resist 60 under standard conditions: touch dry 1 h; actual results are affected by temperature, film thickness and ventilation.
Which standards apply to Resist 60?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Resist 60 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Resist 60

Product description

This is a two-component, moisture-curing inorganic zinc silicate coating. It is a zinc-dust-containing product with good anticorrosive performance, usable with other coatings, and heat resistant up to 540 °C.

Used as a primer in atmospheric environments. For properly prepared carbon steel substrates only. The zinc dust in this product complies with ASTM D520, Type II.

Typical Use

Industrial protective coatings:

For steel structures and pipelines in corrosive environments. Recommended for offshore environments, refineries, power stations, bridges, buildings and mining equipment. Used specifically as a primer in coating systems requiring durability.

Others

Colour

Grey

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323360± 2 %
Gloss (GU 60°)ISO 2813Matt (0–35)
Flash PointISO 3679 Method 116 °C
DensityTheoretical Value2 kg/L
RegionRegulationsTest / StandardVOC Value
USCARB(SCM)2020 / SCAQMD rule 1113US EPA Method 24456 g/L
Hong KongAir Pollution Control (VOC) Regulation456 g/L

The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness50–90 µm
Wet Film Thickness83–150 µm
Theoretical Spreading Rate12–6.7 m²/L

There is a risk of mud cracking if the thickness exceeds 120 µm.

Surface Preparation

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSa 2½ (ISO 8501-1); surface roughness fine to medium G (ISO 8503-2)

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by air spray or airless spray.
Brush:Recommended for stripe coating and small areas. Ensure the specified dry film thickness is achieved. To prevent zinc dust settling, continuous mechanical stirring during application is recommended.

Mixing Ratio (by Volume)

Inorganic Zinc Silicate Primer 5DG, Component A7 parts
Inorganic Zinc Silicate Primer 5DG, Component B1 part

Thinner / Cleaning Solvent

Thinner:JOTUN Thinner No. 4/ JOTUN Thinner No. 25
Maximum thinning:5 %
JOTUN Thinner No. 4To accelerate evaporation
JOTUN Thinner No. 25To slow evaporation

JOTUN Thinner No. 28 may be used in place of JOTUN Thinner No. 4 as a fast-evaporating thinner.

NoteWhere the Korean VOC regulation (Clean Air Conservation Act) and its corresponding thinning limits differ from the recommended thinning volume, the former prevails.

JOTUN Thinner No. 17 may be used as an alternative cleaner.

In China, the cleaning solvent must comply with GB 38508-2020

Airless Spray Guidance

Nozzle tip size (inch/1000):17-21
Nozzle pressure (minimum):100 bar/1400 psi

Drying and Curing Time

Substrate Temperature5 °C10 °C23 °C40 °C
Touch Dry1 h30 min15 min13 min
Walk-on Dry1.5 h1 h30 min25 min
Minimum recoat interval20 h16 h4 h1.5 h
Dry/cured to service20 h16 h4 h1.5 h

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.

The given drying and curing times and overcoating intervals for inorganic zinc silicate are measured at 80% relative humidity during application and curing. Higher relative humidity accelerates curing; curing of this product requires the relative humidity to remain above 50%.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature23 °C
Pot Life5 h

Heat Resistance

Temperature

ContinuousPeak
Drying, atmospheric400°C540 °C

The product can also withstand peak temperatures of 540 °C (1000 °F) for extended periods. However, sustained temperatures above 400 °C affect the long-term service performance of the inorganic zinc silicate coating.

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Subsequent CoatEpoxy, silicone acrylic

Typical Packaging Sizes

VolumeContainer Size
(L)
Inorganic Zinc Silicate Primer 5DG, Component A1420
Inorganic Zinc Silicate Primer 5DG, Component B210

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Inorganic Zinc Silicate Primer 5DG, Component A6 months
Inorganic Zinc Silicate Primer 5DG, Component B48 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — primer, zinc-rich primer

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery