← Back to JOTUN brand page
China-based coatings exporter — industrial & marine protective coatings from China's production bases

Jotacote Xtend GF Ultra-high-solids Abrasion-resistant Epoxy Glass Flake

Quick Specs

Jotacote Xtend GF Ultra-high Solids Abrasion-resistant Epoxy Glass Flake Coating is a glass flake coating of the epoxy system. Recommended for offshore environments, including splash zones, refineries, power stations, bridges, buildings and mining equipment. Suitable for properly prepared carbon steel, stainless steel, aluminium, galvanized steel, concrete and thermal spray zinc substrates. Parameters on this page: volume solids 88 ± 2%, dry film thickness 150–600 µm, theoretical spreading rate 5.87–1.47 m²/L.

Parameter source: JOTUN manufacturer's Technical Data Sheet (TDS) "Jotacote Xtend GF Ultra-high Solids Abrasion-resistant Epoxy Glass Flake Coating"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids88 ± 2%
Dry Film Thickness150–600 µm
Theoretical Spreading Rate5.87–1.47 m²/L
VOC144 g/L (China)
Density / Specific Gravity1.5 kg/L
Number of ComponentsTwo-component
Flash Point32 °C
ThinnerJotun Thinner No. 17
Mixing Ratio3.5 parts : 1 part (by volume)

Browse Similar Models by CategoryThis model belongs to: Glass Flake, Epoxy

FAQ

How many components does Jotacote Xtend GF contain?
Jotacote Xtend GF is a two-component product. Mix according to the mixing ratio in the Application Data table on this page before use.
What is the mixing ratio of Jotacote Xtend GF?
The mixing ratio of Jotacote Xtend GF is 3.5 parts : 1 part (by volume).
What dry film thickness is normally applied for Jotacote Xtend GF?
The conventional dry film thickness of Jotacote Xtend GF is 150–600 µm; the specific value depends on the coating system and design requirements.
What is the theoretical spreading rate of Jotacote Xtend GF?
The theoretical spreading rate of Jotacote Xtend GF is 5.87–1.47 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour opacity.
What is the volume solids of Jotacote Xtend GF?
The volume solids of Jotacote Xtend GF is 88 ± 2%.
What is the VOC content of Jotacote Xtend GF?
The VOC content of Jotacote Xtend GF is 144 g/L (China).
Which thinner is used for Jotacote Xtend GF?
Recommended thinner for Jotacote Xtend GF: Jotun Thinner No. 17.
What is the flash point of Jotacote Xtend GF?
The flash point of Jotacote Xtend GF is 32°C. Storage, transport and application shall follow the product Safety Data Sheet.
How long does Jotacote Xtend GF take to dry?
Drying time of Jotacote Xtend GF under standard conditions: touch dry 15 h; actual values are affected by temperature, film thickness and ventilation.
Which standards apply to Jotacote Xtend GF?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Jotacote Xtend GF be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Jotacote Xtend GF

Product description

Two-component amine-cured abrasion-resistant epoxy glass flake coating. High solids content and low VOC content, with a mass proportion in the paint below 10%. General-purpose primer developed and designed specifically for severe environments requiring long-term corrosion protection design life. In atmospheric and immersion environments it can be used as primer, intermediate coat, topcoat or a single-coat system. Suitable for properly prepared carbon steel, stainless steel, aluminium, galvanized steel, concrete and thermal spray zinc substrates.

Typical Use

Suitable for steel structures and pipelines exposed to "very high" corrosivity categories or to immersion and buried environments. Recommended for offshore environments, including splash zones, refineries, power stations, bridges, buildings and mining equipment. Within a certain dry film range and on the coated areas, the product offers excellent flexibility. Specifically for areas requiring abrasion and impact resistance, such as decks, walkways and landing areas.

Others

Approvals and Certificates

Pre-qualified in the selected coating system in accordance with NORSOK M-501. Other certificates and approvals are available on request.

Colour

Many other colours are available

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323388± 2 %
Gloss (GU 60°)ISO 2813Matt (0–35)
Flash PointISO 3679 Method 132 °C
DensityTheoretical Value1.5 kg/L
RegionRegulationsTest / StandardVOC Value
ChinaMandatory national standard of ChinaGB 30981.2-2025144 g/L
Coating hazards GB30981.2-S-Pb≤1000-NC

The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness150–600 µm
Wet Film Thickness171–682 µm
Theoretical Spreading Rate5.87–1.47 m²/L

Surface Preparation

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSt 2 (ISO 8501-1)Sa 2½ (ISO 8501-1)
Stainless steelThe surface should be blasted with a non-metallic abrasive,“Blast clean using an approved non-metallic abrasive
hand- or machine-sanded using abrasive paper or fibre discs,to produce a sharp angular surface profile.”

to produce scratch marks on the surface.

AluminiumThe surface should be abraded by hand or machine using a non-metallic abrasive, fibre discs or abrasive paper to produce scratch marks.
Galvanised steelThe surface should be clean, dry and have a suitable profileSweep blast with a non-metallic abrasive to produce a clean,
°a rough and uniform surface.
Shop-primed SteelDry, clean, intact shop primerSweep blast or abrasive blast clean at least 70% of the area to Sa 2 (ISO 8501-1)
ConcreteCuring time of at least 4 weeks. Maximum moisture 5%. For existingCuring time of at least 4 weeks. Maximum moisture 5%. Seal with
Concrete surfaces: sanding, needle gun and mechanical grindingClosed-circuit blasting, diamond grinding and other suitable methods
and similar, by mechanical treatmentto treat the surrounding concrete surface to remove laitance.
Coated surfaceA clean, dry and sound compatible primer.

The recommended surface preparation provides optimum properties including adhesion, corrosion resistance, heat resistance and chemical resistance.

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by airless spray.
Brush:Recommended for touch-up and small-area application. Take care to achieve the specified dry film thickness.

Mixing Ratio (by Volume)

Jotacote Xtend GF Comp A3.5 parts
Jotacote Xtend GF Comp B1 part

Thinner / Cleaning Solvent

ThinnerJotun Thinner No. 17

Airless Spray Guidance

Nozzle tip size (inch/1000):21-25
Nozzle pressure (minimum):200 bar / 2900 psi

Drying and Curing Time

Substrate Temperature0 °C5 °C10 °C15 °C23 °C40 °C
Touch Dry15 h9 h6 h5 h3.5 h2 h
Walk-on Dry45 h27 h19 h15 h8 h3.5 h
Minimum recoat interval30 h22 h15 h11 h6 h2.5 h
Dry/cured to service12 days10 days7 days

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are measured at a dry film thickness of 300 µm under controlled temperature and relative humidity below 85%.

Extra care is required when overcoating at low temperatures; the whole coating system requires higher temperatures to cure and develop good mechanical strength.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature23 °C
Pot Life1 h

Heat Resistance

Temperature

Drying, atmosphericContinuous 120 °CPeak 140 °C
Immersed, sea water50 °C-

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous coat:Epoxy, modified epoxy, zinc-rich epoxy, zinc silicate, inorganic zinc silicate shop primer
Subsequent coat:Acrylic, epoxy, polyurethane, polysiloxane

Typical Packaging Sizes

VolumeContainer Size
(L)
Jotacote Xtend GF Comp A1420
Jotacote Xtend GF Comp B45

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Jotacote Xtend GF Comp A24 months
Jotacote Xtend GF Comp B24 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Environmental documentation

This product can contribute to green building standard credits. Visit Jotun.com for more information or contact your local JOTUN representative.

EPDs are available at www.epd-norge.no

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — glass flake coating, epoxy coating

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery