China-based coatings exporter — industrial & marine protective coatings from China's production bases

Jotun Inhibitive Oil

Quick Specs

Jotun Inhibitive Oil JOTUN Anti-rust Oil belongs to Primer. Marine coatings field: designed for short-term protection of fuel oil tanks during newbuilding. For use alone in atmospheric and immersion environments. Parameters on this page: volume solids 50 ± 2%, dry film thickness 20–30 µm, theoretical spreading rate 25–16.7 m²/L. Comparable models from the same brand: Jota-Etch Etching Primer, Jotamastic Smart Pack HB Easy-to-Apply 1+1 High-build Primer, Jotamastic Smart Pack Easy-to-Apply 1+1 Primer.

Parameter source: JOTUN original technical data sheet (TDS) “Jotun Inhibitive Oil JOTUN Anti-rust Oil”; values such as spreading rate are converted from TDS parameters and are for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids50 ± 2%
Dry Film Thickness20–30 µm
Theoretical Spreading Rate25–16.7 m²/L
VOC399 g/L (China)
Density / Specific Gravity0.95 kg/L
Number of ComponentsOne-component
Flash Point38 °C
ThinnerJOTUN Thinner No. 2
GlossGloss (70–85)

Browse Similar Models by CategoryThis model belongs to: Primer

FAQ

How many components does Jotun Inhibitive Oil have?
Jotun Inhibitive Oil is a one-component product; it can be applied after stirring uniformly in the can, with no on-site mixing required.
What dry film thickness is typically applied for Jotun Inhibitive Oil?
The conventional dry film thickness of Jotun Inhibitive Oil is 20–30 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Jotun Inhibitive Oil?
The theoretical spreading rate of Jotun Inhibitive Oil is 25–16.7 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Jotun Inhibitive Oil?
The volume solids of Jotun Inhibitive Oil is 50 ± 2%.
What is the VOC of Jotun Inhibitive Oil?
The VOC of Jotun Inhibitive Oil is 399 g/L (China).
What is the gloss of Jotun Inhibitive Oil?
The gloss of Jotun Inhibitive Oil is Glossy (70–85).
Which thinner is used for Jotun Inhibitive Oil?
Recommended thinner for Jotun Inhibitive Oil: JOTUN Thinner No. 2.
What is the flash point of Jotun Inhibitive Oil?
The flash point of Jotun Inhibitive Oil is 38 °C. Storage, transport and application shall be carried out in accordance with the product Safety Data Sheet.
How long does Jotun Inhibitive Oil take to dry?
Drying time of Jotun Inhibitive Oil under standard conditions: touch dry 30 min; actual results are affected by temperature, film thickness and ventilation.
Which standards apply to Jotun Inhibitive Oil?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Jotun Inhibitive Oil be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Jotun Inhibitive Oil

Product description

This is a one-component physically drying inhibitive oil. Suitable for short-term protection of fuel tanks prior to commissioning. For use alone in atmospheric and immersion environments. Suitable for properly prepared carbon steel substrates.

Typical Use

Marine coatings:

Designed for short-term protection of fuel tanks during newbuilding. Compatible with common fuels.

Others

Colour

Colourless

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323350± 2 %
Gloss (GU 60°)ISO 2813Gloss (70–85)
Flash PointISO 3679 Method 138 °C
DensityTheoretical Value0.95 kg/L
RegionRegulationsTest / StandardVOC Value
USCARB(SCM)2020 / SCAQMD rule 1113Calculation414 g/L
Hong KongAir Pollution Control (VOC) RegulationCalculation414 g/L
EUEuropean Paint Directive 2004/42/CECalculation414 g/L
ChinaGB 30981-2020 Limit of harmful substances of industrial protective coatingsGB/T 23985-2009 8.3399 g/L

The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness20–30 µm
Wet Film Thickness40–60 µm
Theoretical Spreading Rate25–16.7 m²/L

Surface Preparation

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Carbon SteelSt 2 (ISO 8501-1)Sa 2½ (ISO 8501-1)
Shop-primed SteelClean, dry and intact shop primer (compliant with ISO 12944-4 clause 5.4).St 2 (ISO 8501-1)

Application

Application Methods

This product may be applied by the following methods

Spray:Apply by air spray or airless spray.
Brush:Recommended
Roller:Recommended

Product mixing

One-component

Thinner / Cleaning Solvent

ThinnerJOTUN Thinner No. 2

In China, the cleaning solvent must comply with GB 38508-2020

Airless Spray Guidance

Nozzle tip size (inch/1000):13-17
Nozzle pressure (minimum):100 bar/1450 psi

Drying and Curing Time

Substrate Temperature5 °C10 °C23 °C40 °C
Touch Dry30 min20 min10 min5 min
Walk-on Dry3.5 h3 h2 h1.5 h
Minimum recoat interval3.5 h3 h2 h1.5 h

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous CoatInorganic Zinc Silicate Shop Primer

Typical Packaging Sizes

VolumeContainer Size
(L)
JOTUN Inhibitive Oil5 / 20

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

JOTUN Inhibitive Oil 48 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — primer

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery