Hardtop F15 HS Alu Fluoropolymer Coating

Quick Specs

Hardtop F15 HS Alu Fluoropolymer Coating is a fluorocarbon coating used as a topcoat. In the industrial protective coatings sector: recommended for refineries, power stations, bridges and buildings. Its film has an aluminium gloss surface with high gloss retention. Parameters on this page: volume solids 54 ± 2%; dry film thickness 30–60 µm; theoretical spreading rate 18–9 m²/L. Comparable products from the same brand: Hardtop F10 Alu Fluorocarbon Aluminium Topcoat F10, Hardtop F10 HS High-solids Fluorocarbon Topcoat F10, Hardtop F10 Fluorocarbon Topcoat F10.

Source: JOTUN original technical data sheet (TDS) 'Hardtop F15 HS Alu Fluoropolymer Coating'. Spreading rate and other values converted from the TDS; for reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids54 ± 2%
Dry Film Thickness30–60 µm
Theoretical Spreading Rate18–9 m²/L
VOC383 g/L (China)
Density / Specific Gravity1.1 kg/L
Number of ComponentsTwo-component
Flash Point27 °C
ThinnerJOTUN Thinner No. 26
Mixing Ratio7 parts : 1 part (by volume)

Browse Similar Models by CategoryThis model belongs to: Topcoat, Fluorocarbon

FAQ

How many components does Hardtop F15 HS Alu contain?
Hardtop F15 HS Alu is a two-component product. Mix to the ratio shown in the Application Data table on this page before use.
What is the mixing ratio of Hardtop F15 HS Alu?
Mixing ratio of Hardtop F15 HS Alu: 7 parts : 1 part (by volume).
What is the typical dry film thickness of Hardtop F15 HS Alu?
Typical dry film thickness of Hardtop F15 HS Alu: 30–60 µm; final value depends on the coating system and design requirements.
What is the theoretical spreading rate of Hardtop F15 HS Alu?
Theoretical spreading rate of Hardtop F15 HS Alu: 18–9 m²/L; actual consumption varies with substrate roughness, application loss and colour hiding power.
What is the volume solids of Hardtop F15 HS Alu?
Volume solids of Hardtop F15 HS Alu: 54 ± 2%.
What is the VOC of Hardtop F15 HS Alu?
VOC of Hardtop F15 HS Alu: 383 g/L (China).
Which thinner is recommended for Hardtop F15 HS Alu?
Recommended thinner for Hardtop F15 HS Alu: Jotun Thinner No. 26.
What is the flash point of Hardtop F15 HS Alu?
Flash point of Hardtop F15 HS Alu: 27 °C. Storage, transport and application per the product safety data sheet.
How long does Hardtop F15 HS Alu take to dry?
Drying time of Hardtop F15 HS Alu under standard conditions: touch dry 2 h; actual values depend on temperature, film thickness and ventilation.
Which standards apply to Hardtop F15 HS Alu?
As recorded in the technical data on this page: ISO 3233 (see the application instructions on this page); ISO 2813 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Hardtop F15 HS Alu be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Hardtop F15 HS Alu

Product description

A two-component chemically curing fluoropolymer coating. Its film has an aluminium gloss surface with high gloss retention. The product contains aluminium flake pigment. Used as a topcoat in atmospheric environments.

Typical Use

Industrial protective coatings:

Recommended for refineries, power stations, bridges and buildings. Widely suitable for industrial structures.

Others

Colour

RAL 9006, RAL 9007. Different application methods, dry film thickness, temperature, humidity and substrate give different results.

Due to technical limitations, exact matching of metallic topcoat colours is not possible

Product Data

PropertyTest / StandardDescription
Volume SolidsISO 323354± 2 %
Gloss (GU 60°)ISO 2813Semi-gloss (35–70)
Flash PointISO 3679 Method 127 °C
DensityTheoretical Value1.1 kg/L
RegionRegulationsTest / StandardVOC Value
USCARB(SCM)2020 / SCAQMD rule 1113Calculation411 g/L
Hong KongAir Pollution Control (VOC) RegulationCalculation411 g/L
EUEuropean Paint Directive 2004/42/CECalculation411 g/L
ChinaGB 30981-2020 Limit of harmful substances of industrial protective coatingsGB/T 23985-2009 8.3383 g/L

The data listed are based on factory batch production and may vary slightly with colour.

Gloss descriptionAccording to JOTUN's definition of functional coatings

Film Thickness per Coat

Typical recommended specification range

Dry Film Thickness30–60 µm
Wet Film Thickness55–110 µm
Theoretical Spreading Rate18–9 m²/L

A light-coloured primer improves the visual effect of aluminium colours. Note that hiding power may vary with film thickness.

Surface Preparation

Surface Preparation Summary

Surface Preparation

SubstrateMinimumRecommended
Coated surfaceA clean, dry and sound compatible primer.

Application

Application Methods

This product may be applied by the following methods

Spray:Use air spray, airless spray or air-assisted spray.
Brush:Not recommended
Roller:Not recommended

Different application methods or techniques may produce different metallic effects. For more details, refer to the Application Guide or other JOTUN documents.

Mixing Ratio (by Volume)

Hardtop F15 HS Alu Comp A7 parts
High-Solids Fluorocarbon Topcoat F10 / F15 / F20, Component B1 part

The paint shall be stirred with clean, suitable mechanical stirring tools. Stir Component A thoroughly before adding any Component B or thinner. Add Component B before adding any thinner, and stir Components A and B thoroughly with a stirring tool.

Thinner / Cleaning Solvent

ThinnerJOTUN Thinner No. 26

Different thinning ratios may give different colours, and an excessively high thinner ratio may affect the uniformity of the coating.

In China, the cleaning solvent must comply with GB 38508-2020

Airless Spray Guidance

Nozzle tip size (inch/1000):11-15
Nozzle pressure (minimum):150 bar/2100 psi. For more information, refer to the application guide.

Air spray guidance

Nozzle tip size:13–15 (inch/1000) / pressure pot: 1.3–1.5 (mm)
Nozzle pressure (minimum):2.1 bar/30 psi / pressure pot: 2.1 bar/30 psi

Fluctuations in gun tip pressure may affect the orientation of aluminium flakes and the brightness of the film.

Drying and Curing Time

Substrate Temperature5 °C10 °C23 °C40 °C
Touch Dry2 h1 h30 min20 min
Walk-on Dry40 h20 h10 h5 h
Minimum recoat interval32 h16 h8 h4 h
Dry/cured to service20 days15 days7 days3 days

For the maximum recoat interval, refer to the Application Guide (AG) for this product.

Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.

Touch DryThe state at which light finger pressure leaves no mark or stickiness.
Walk-on DryThe minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage.

Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.

Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.

Induction Time and Pot Life

Paint temperature23 °C
Pot Life5 h

Heat Resistance

Temperature

ContinuousPeak
Drying, atmospheric120°C140 °C

Withstands peak temperatures for a maximum of one hour.

At the above temperatures, protective performance is unaffected, but appearance may be affected.

Product Compatibility

Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.

Previous coat:Epoxy, modified epoxy, polyurethane
Subsequent coat:Fluoropolymer

Typical Packaging Sizes

VolumeContainer Size
(L)
Hardtop F15 HS Alu Comp A12.620
High-Solids Fluorocarbon Topcoat F10 / F15 / F20, Component B1.83

The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.

Storage

Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.

Shelf Life at 23 °C

Hardtop F15 HS Alu Comp A48 months
High-Solids Fluorocarbon Topcoat F10 / F15 / F20, Component B48 months

In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.

Precautions

For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.

Health and Safety

Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.

Colour Variation

When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.

Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.

Disclaimer

The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.

Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.

In case of any discrepancy between language versions, the English (UK) version shall prevail.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — topcoat, fluorocarbon coating

View all JOTUN models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery