Chemclear Vinyl Ester High-Strength Acid-Resistant Sealer is a vinyl ester coating used as a primer. Industrial protective coatings: specifically a lining coating for tanks, used with glass fibre sheets. A chemical-resistant, fast-curing sealer that can be used as a primer in the entire coating system. Parameters on this page: volume solids 96 ± 2%, dry film thickness 150-300 µm, theoretical spreading rate 6.4-3.2 m²/L. Comparable models from the same brand: Alkydprimer alkyd primer, Balloxy BT modified epoxy primer BT, Jota AK15P fast-drying alkyd primer AK15P.
Parameter source: JOTUN original technical data sheet (TDS) for Chemclear Vinyl Ester High-Strength Acid-Resistant Sealer; spreading rate and other values are converted from TDS parameters and provided for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 96 ± 2% |
|---|---|
| Dry Film Thickness | 150–300 µm |
| Theoretical Spreading Rate | 6.4-3.2 m²/L |
| VOC | 7 g/L (US) |
| Density / Specific Gravity | 1 kg/L |
| Number of Components | — |
| Flash Point | 34 °C |
| Thinner | Styrene |
| Gloss | Gloss (70–85) |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
Chemclear
It is a vinyl ester coating. A chemical-resistant, fast-curing sealer that can be used as a primer in the entire coating system. Suitable for use with glass fibre sheets. It can be used as a primer in atmospheric and immersed environments. Suitable for properly prepared carbon steel and concrete surfaces.
Industrial protective coatings:
Specifically a lining coating for tanks, used with glass fibre sheets. Used as a sealer for Chemflake products on carbon steel and concrete substrates.
Others
Colourless (yellowing)
| Property | Test / Standard | Description |
| Volume Solids | Theoretical Value | 96± 2 % |
| Gloss (GU 60°) | ISO 2813 | Gloss (70–85) |
| Flash Point | ISO 3679 Method 1 | 34 °C |
| Density | Theoretical Value | 1 kg/L |
| Region | Regulations | Test / Standard | VOC Value |
| US | CARB(SCM)2020 / SCAQMD rule 1113 | Calculation | 7 g/L |
| Hong Kong | Air Pollution Control (VOC) Regulation | Calculation | 7 g/L |
| EU | European Paint Directive 2004/42/CE | Calculation | 7 g/L |
The data listed are based on factory batch production and may vary slightly with colour.
| Gloss description | According to JOTUN's definition of functional coatings |
|---|
Typical recommended specification range
| Dry Film Thickness | 150–300 µm |
| Wet Film Thickness | 160-315 µm |
| Theoretical Spreading Rate | 6.4-3.2 m²/L |
| Practical consumption on concrete | 0.15-0.3 L/m². All vinyl ester and polyester coatings may shrink during curing. This causes the practical spreading rate to be lower than the theoretical spreading rate. The shrinkage depends on the actual dry film thickness and application conditions. |
|---|
Surface Preparation
| Substrate | Minimum | Recommended |
| Concrete | Curing time of at least 4 weeks. Maximum moisture 5%. Seal with | At least 4 weeks of curing time. Maximum moisture 5%. Dry grind |
| Closed-circuit blasting, diamond grinding and other suitable methods | abrasive blast cleaning to SSPC-SP 13/NACE No. 6. |
to treat the surrounding concrete surface to remove laitance.
| Carbon Steel | Sa 2½ (ISO 8501-1); surface roughness medium to coarse G (ISO 8503-2) | |
This product may be applied by the following methods
| Spray: | Standard airless spray may be used. Dedicated two-component airless spray is optional. |
| Brush: | Recommended |
| Roller: | Recommended |
The substrate temperature must not be below the paint temperature, nor more than 20 °C above it.
Additive addition per 16 L of product (ml).
Due to differing regional regulations, packaging sizes and fill capacities may vary by region. Adjust the quantity of additive accordingly.
Paint temperature
Additive 15-19 °C 20-24 °C Jotun Peroxide No. 1, Norox KP-9 or 400 400 Butanox M-50
| Thinner: | Styrene |
| Maximum thinning: | 20 % |
If used as a sealer, thinning is required. Normally no thinning is required. For application in extreme environments, consult the local Jotun representative. Do not thin beyond local environmental regulations.
| Cleaner | Acetone / Jotun Thinner No. 17 / Jotun Thinner No. 23 |
|---|
When the thinner is used as a cleaning solvent, it must first comply with local regulatory requirements
In China, the cleaning solvent must comply with GB 38508-2020
| Nozzle tip size (inch/1000): | 19-23 |
| Nozzle pressure (minimum): | 150 bar/2100 psi |
| Substrate Temperature | 15 °C | 23 °C | 40 °C |
| Touch Dry | 4 h | 2 h | 1 h |
| Walk-on Dry | 4 h | 2 h | 1 h |
| Minimum recoat interval | 4 h | 2 h | 1 h |
| Maximum recoat interval (immersion environment) | 1 day | ||
| Dry/cured to service | 8 days | 4 days | 2 days |
For the maximum recoat interval, refer to the Application Guide (AG) for this product.
Drying and curing times are determined based on temperature and relative humidity below 85%, with dry film thickness within the average range.
| Touch Dry | The state at which light finger pressure leaves no mark or stickiness. |
|---|---|
| Walk-on Dry | The minimum time after which the coating allows normal foot traffic without leaving permanent footprints, marks or other physical damage. |
Minimum recoat interval after drying: the recommended minimum interval before applying the next coat.
Maximum recoat interval (immersion environment): the maximum time interval before the next coat may be applied without any surface preparation.
Dry/cured to service: the minimum time before the coating can be permanently exposed to a specific environment/medium.
| Paint temperature | 23 °C |
| Pot Life | 20 min |
Temperature
| Drying, atmospheric | Continuous 140 °C | Peak - |
| Immersed, sea water | 85 °C | - |
Note: this coating can withstand different immersion temperatures, depending on the specific chemical and whether immersion is continuous or intermittent. Heat resistance is affected by the coating system as a whole. When used with other coatings, ensure that all coatings in the system have similar heat resistance.
Depending on the actual exposure conditions in service, this product may be used with various primers and topcoats. Some reference systems are listed below. For specific systems, contact JOTUN.
| Previous coat: | Unsaturated vinyl ester |
| Subsequent coat: | Unsaturated vinyl ester |
| Volume | Container Size | |
| (L) | ||
| Vinyl Ester High-Strength Acid-Resistant Sealer | 16 | 20 |
The packaging sizes above are typical reference sizes for factory batch production. Due to regional regulatory differences, packaging sizes and capacities may vary by region.
Store in accordance with national regulations. Keep containers in a dry, cool, well-ventilated place away from heat and sources of ignition. Keep containers tightly closed. Handle with care.
Vinyl Ester High-Strength Acid-Resistant Sealer 4 months
In some markets, the stated shelf life may be shortened to comply with local legal requirements. The above is the minimum shelf life; thereafter, testing is required to confirm quality remains acceptable.
For professional use only. Applicators and workers must be trained, experienced, capable and equipped to mix, stir and apply the coating correctly in accordance with JOTUN's technical documents. Applicators and workers must wear appropriate personal protective equipment when using this product. This guidance is provided based on current product knowledge. Any proposed modification to suit site conditions must be approved by the responsible JOTUN representative before use.
Read the safety warnings on the container packaging. Use in well-ventilated conditions. Avoid inhaling spray mist and avoid skin contact. In case of accidental splashes on skin, wash immediately with a suitable cleaner, soap and water. In case of eye contact, rinse thoroughly with water and seek medical attention immediately.
When used primarily as a primer or antifouling coating, products may show slight colour variation from batch to batch. Such products, and epoxy products used as topcoats, may chalk when exposed to sunlight.
Gloss and colour retention of topcoats depend on the colour type, the surrounding environment such as temperature and UV intensity, application quality and product type. Contact your local JOTUN office for further information.
The information in this datasheet is based entirely on knowledge gained in our laboratory and in practice. JOTUN products are regarded as semi-finished products, and their use is generally beyond our control. JOTUN therefore guarantees only the quality of the product itself. To comply with local regulations, the product may be adjusted, and we reserve the right to modify the datasheet without further notice.
Users should consult JOTUN for specific guidance on the suitability of the product for their requirements and applications.
In case of any discrepancy between language versions, the English (UK) version shall prevail.
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.