Intersleek 2120 Elastomeric Foul-release Coating

Quick Specs

Intersleek 2120 Foul Release Coating belongs to Antifouling. A three-component silicone elastomer foul release coating. Parameters on this page: Volume Solids 72% ± 2%, Dry Film Thickness (DFT) 150 µm, Theoretical Spreading Rate 4.80 m²/L. Comparable models from the same brand: Intercept 7000 Linear Polishing Antifouling, Intercept 8500 LPP Tin-free Linear Polishing Polymer Antifouling, Interflex 8700 SPC Tin-free Self-Polishing Copolymer Antifouling.

Parameter source: International INTERNATIONAL original technical data sheet (TDS) “Intersleek 2120 Foul Release Coating”; values such as spreading rate are converted from TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids72% ± 2%
Dry Film Thickness150 µm
Theoretical Spreading Rate4.80 m²/L
VOC254 g/L (as supplied) (EPA Method 24) 241 g/kg (…
Density / Specific Gravity—
Number of ComponentsThree-component
Mixing RatioComponent A : Component B : Component C = 7.5:2:0.5 (by volume)
Colour / AppearanceBXA211-Grey, BXA212-Red, BXA213-Black, BX…
Gloss

Browse Similar Models by CategoryThis model belongs to: Antifouling

FAQ

How many components does Intersleek 2120 have?
Intersleek 2120 is a three-component product, used after mixing at the ratio given in the "Application Data" table on this page.
What is the mixing ratio of Intersleek 2120?
The mixing ratio of Intersleek 2120 is Component A:Component B:Component C = 7.5:2:0.5 (by volume).
What dry film thickness is typically applied for Intersleek 2120?
The conventional dry film thickness of Intersleek 2120 is 150 µm; the specific value is determined by the coating system and design requirements.
What is the theoretical spreading rate of Intersleek 2120?
The theoretical spreading rate of Intersleek 2120 is 4.80 m²/L; actual consumption is adjusted according to substrate roughness, application loss and colour hiding power.
What is the volume solids of Intersleek 2120?
The volume solids of Intersleek 2120 is 72% ± 2%.
What is the VOC of Intersleek 2120?
The VOC of Intersleek 2120 is 254 g/L (as supplied) (EPA Method 24) 241 g/kg (….
What is the gloss of Intersleek 2120?
The gloss of Intersleek 2120 is Glossy.
What is the flash point of Intersleek 2120?
The flash point of Intersleek 2120 is Component A 41°C; Component B 22°C; Component C 32°C; after mixing 30°C. Storage, transport and application shall follow the product safety data sheet.
How is Intersleek 2120 applied?
Application method for Intersleek 2120: airless spray, brush and roller; surface preparation and the coating system are as described on this page.
Which standards does Intersleek 2120 involve?
As recorded in the technical data on this page: ISO 3233:1998 (see the application instructions on this page); ISO 9117 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Intersleek 2120 be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product overview

A three-component silicone elastomer foul release coating.

Intended use

For maintenance and repair.

Product information

ColourBXA211-Grey, BXA212-Red, BXA213-Black, BXA214-White
Topcoat/glossGloss
Component B (curing agent)BXA216 (Component B), BXA217 (Component C)
Volume Solids72% ±2% (ISO 3233:1998)
Mixing ratioComponent A : Component B : Component C = 7.5:2:0.5 (by volume)
Standard film thickness150 µm DFT (208 µm WFT)
Theoretical Spreading RateAt 150 µm dry film thickness the theoretical spreading rate is 4.80 m²/L, allowing for appropriate loss factors
Application MethodsAirless spray, brush, roller
Flash PointComponent A 41 °C; Component B 22 °C; Component C 32 °C; after mixing 30 °C
Drying data5°C15°C25°C35°C
Touch dry [ISO 9117/3:2010]10 h6 h3 h1 h
Hard dry [ISO 9117-1:2009]13 h8 h5 h2 h
Before launching48 h36 h20 h17 h
Pot life after mixing180 min100 min60 min30 min
NoteBetween 5 °C and 20 °C, the interval before launching may be reduced to 24 hours, provided the vessel berths for at least 2–3 days after launching. Between 0 °C and 5 °C, the minimum time before launching is 48 hours, and the vessel shall berth for at least 4 days after leaving dry dock. However, the coating may delaminate in any areas subject to mechanical wear (for example, from fendering or impact damage).
Recoat data — see the “Limitations” sectionSubstrate Temperature
5°C15°C25°C35°C
When recoating the following productsMinimumMaximumMinimumMaximumMinimumMaximumMinimumMaximum
NoteMay be overcoated with itself, both on fresh coatings and on coatings after prolonged immersion, provided the surface is in good, clean condition. Consult International Paint.

Regulatory data

Volatile Organic Compounds254 g/L (as supplied) (EPA Method 24) 241 g/kg (as supplied liquid paint). EU Solvent Emissions Directive (Council Directive 1999/13/EC) The volatile organic compound value is typical and is provided for reference only. It may vary with factors such as colour and normal manufacturing tolerances.

This product contains no organotin compounds acting as biocides and complies with the international treaty adopted by the IMO in October 2001 on the control of harmful antifouling systems on ships (IMO document AFS/CONF/26).

Certificates

When used as part of an approved scheme, this product holds the following certificates: The product has been approved by the following classification societies in accordance with the International Convention on the Control of Harmful Anti-fouling Systems on Ships, 2001 (AFS 2001): • DNV For details, consult the local International (International Paint) representative.

System and compatibility

For the paint system best suited to the surface to be protected, consult your local International Paint representative.

Surface Preparation

Apply in accordance with the supplied instructions.

All surfaces to be coated shall be clean, dry and free from contaminants. Use high-pressure fresh water washing or general fresh water washing, as appropriate, and remove all oil, grease, soluble contaminants and other foreign matter in accordance with SSPC-SP1 solvent cleaning standard. For other cleaning methods, consult International (International Paint).

Intersleek 2120 must always be applied over the Intersleek tie coat within the specified overcoating interval.

For detailed application advice, consult International Paint.

Application

Mixing

The coating is supplied in three containers as one unit. Always mix the entire unit in the supplied ratio.

(1) Stir Component A with a power mixer.

(2) Mix all of Component A with Component B and stir thoroughly with a power mixer.

(3) Add all of Component C and stir thoroughly with a power mixer.

Carefully (with slow power stirring) add Component C to the Component A/Component B mixture. These products are moisture-sensitive and shall be opened only when needed.

Thinner

Not recommended. Only in special cases, use International GTA007 (maximum 5% by volume). Do not thin beyond the limits of local environmental regulations.

Airless Spray

Recommended nozzle size 0.38–0.53 mm (15–21 thou); total output fluid pressure at the nozzle not less than 211 kg/cm² (3000 psi)

Conventional spray

Conventional spray application is not recommended.

Brush

Brush application is recommended only for repair areas. Multiple coats may be required to achieve the specified film thickness.

Roller application

Brush application is recommended for small areas only. Several coats may be required to achieve the specified film thickness.

Cleaner

Interruption of work and cleaning

Do not allow paint to remain in hoses, spray guns or spray equipment. Thoroughly flush all equipment with International GTA007. Once a paint unit has been mixed, it shall not be resealed; if application is interrupted for an extended period, remixing of the components before resuming application is recommended.

All equipment shall be cleaned with International GTA007/GTA822 immediately after use. Spray equipment shall be flushed with acetone. Flushing the spray equipment at regular intervals during the working day is good practice. The frequency of cleaning depends on the amount sprayed, the temperature and the time in use (including delays). At the start, flush GTA007/GTA822 out of the lines with acetone. Do not exceed the pot life after mixing.

All surplus paint and empty containers must be disposed of in accordance with appropriate local regulations/laws.

Welding

If welding or flame cutting is performed on metal coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation. In North America, follow the instructions in ANSI/ASC Z49.1 “Safety in Welding and Cutting”.

Safety

All work related to the application and use of this product must comply with national health, safety and environmental protection standards and regulations.

Before using this product, obtain, read and follow the health and safety information in the Material Safety Data Sheet for the product. Read and observe all precautions in the Material Safety Data Sheet and on the container label. If these warnings and requirements are not fully understood, or cannot be strictly observed, do not use the product. During application and drying of the product, provide adequate ventilation and protective measures to keep solvent vapour concentrations within safe limits, so as to prevent poisoning or oxygen deficiency. Take protective measures to avoid skin and eye contact with the product (e.g. gloves, goggles, face shield, barrier cream). Specific safety measures depend on the application method and working environment.

Emergency contact: USA/Canada — medical 1-800-854-6813; Europe — tel. (44) 191 4696111, hospital and doctor (44) 207 6359191; other regions — contact the regional office

Limitation

The minimum substrate temperature acceptable during application is +5 °C. A minimum relative humidity of 30% is required to ensure proper curing. If relative humidity is below 30%, a longer curing time will be required. Care shall be taken to avoid overspray in areas where conventional application is used. Intersleek 2120 must always be applied over the Intersleek tie coat within the specified overcoating interval. All equipment must be thoroughly cleaned before use or before use of other paints to prevent contamination. Liquid cleaners not permitted for Intersleek 2120 shall not be allowed to contaminate other paints.

Overcoating data are for guidance only and shall depend on local climatic and environmental conditions. For specific advice, consult the local International (International Paint) representative. Apply in good weather. The temperature of the surface to be coated must be at least 3 °C above the dew point. Unless otherwise specifically instructed, the paint temperature shall be maintained at 21 °C before mixing and application to achieve optimum performance. Unmixed paint (in tightly closed containers) shall be stored protectively as specified in the Storage section of this product data sheet. The technical and application data mentioned herein are intended to provide general guidelines for establishing a paint application programme. Test performance results are derived from controlled laboratory conditions; International (International Paint) cannot assert that the published test results, or any other tests, precisely represent

Packaging Specifications

Packaging SpecificationsComponent AComponent BComponent C
VolumePackagingVolumePackagingVolumePackaging
10 L7.5 L10 L2 L2.5 L0.5 L1 L
2.5 US gal1.88 US gal2.5 US gal0.5 US gal1 US pint

For other packaging sizes, consult International Paint.

Unit shipping weight

Packaging SpecificationsPackaging weight
10 L12.1 kg
2.5 US gal24 lb

Storage

Shelf lifeAt 25 °C, minimum 12 months. Thereafter, re-inspection is required. Store in a dry, sheltered place away from heat and sources of ignition.

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — antifouling coating

View all INTERNATIONAL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery