Interlac 497 Alkyd Intermediate Coat is an alkyd coating used as an intermediate coat. For newbuilding, maintenance and repair or in-service maintenance. A one-component alkyd intermediate coat. Parameters on this page: volume solids 52% ± 2%, dry film thickness 40 µm, theoretical spreading rate 13 m²/L. Comparable products of the same brand and type: Interlac 678 Alkyd Clear Coat, Interstores Alkyd Primer multi-purpose primer, Interstores Alkyd Topcoat.
Parameter source: International manufacturer's Technical Data Sheet (TDS) "Interlac 497 Alkyd Intermediate Coat"; values such as spreading rate are converted from TDS parameters and are for product selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.
This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.
| Volume Solids | 52% ± 2% |
|---|---|
| Dry Film Thickness | 40 µm |
| Theoretical Spreading Rate | 13 m²/L |
| VOC | 391 g/L (as supplied) (EPA Method 24) 274 g/kg(… |
| Density / Specific Gravity | — |
| Number of Components | One-component |
| Mixing Ratio | N/A |
| Colour / Appearance | CRB000 white, CRE939 blue, CRY999 black |
| Gloss | Matt |
For more Q&A on selection, application, acceptance and defect diagnosis, seeFAQsection.
One-component alkyd intermediate coat.
For internal and external use in above-water areas.
For newbuilding, maintenance and repair, or in-service maintenance.
| Colour | CRB000 white, CRE939 blue, CRY999 black |
|---|---|
| Topcoat/gloss | Matt |
| Component B (curing agent) | N/A |
| Volume Solids | 52% ±2% (ISO 3233:1998) |
| Mixing ratio | N/A |
| Standard film thickness | 40 µm dry film thickness (77 µm wet film thickness) |
| Theoretical Spreading Rate | Theoretical spreading rate 13 m²/L at 40 µm dry film thickness, allowing for appropriate loss factors |
| Application Methods | Airless spray, brush, conventional spray, roller |
| Flash Point | One-component 39°C |
| Drying data | -5°C | 5°C | 25°C | 35°C |
| Touch dry [ISO 9117/3:2010] | 24 h | 10 h | 4 h | 1.5 h |
| Hard dry [ISO 9117-1:2009] | 48 h | 24 h | 20 h | 8 h |
| Recoat data — see the “Limitations” section | Substrate Temperature |
|---|
| When recoating the following products | -5 °C minimum | -5 °C maximum | 5 °C minimum | 5 °C maximum | 25 °C minimum | 25 °C maximum | 35 °C minimum | 35 °C maximum |
| Interlac 665 | 48 h | 14 days | 30 h | 14 days | 24 h | 10 days | 16 h | 5 days |
| Volatile Organic Compounds | 391 g/L (as supplied) (EPA Method 24) 274 g/kg (as supplied liquid paint). EU Solvent Emissions Directive (Council Directive 1999/13/EC) 414 g/L China national standard GB23985. Volatile organic compound values are typical values and are provided for reference only. They may vary with factors such as colour and normal manufacturing tolerances. |
|---|
Coating hazards GB 30981.2-S-Pb≤1000-NC; complies with GB 30981.2-2025
For the paint system best suited to the surface to be protected, consult your local International Paint representative.
Applied in accordance with the standard Worldwide Marine Specifications.
All surfaces to be coated must be clean, dry and free of contaminants.
Wash with high-pressure or ordinary fresh water as appropriate, and remove all oil, grease, soluble contaminants and other foreign matter in accordance with the SSPC-SP1 solvent cleaning standard.
Newbuilding/major refurbishment: Interlac 497 should always be applied over the recommended primer. The primer surface should be dry and free from any contamination, and Interlac 497 must be applied within the specified recoat interval (refer to the relevant product Data Sheet). Areas of damage or defects should be prepared to the specified standard (e.g. Sa2.5 (ISO 8501-1:2007)) and primed before application of Interlac 497.
Repair: touch up corroded areas with a suitable International Paint primer (refer to the primer Data Sheet).
For specific advice, consult your local International Paint representative.
This coating is a single-component product; stir thoroughly with a power mixer before application.
International GTA004. Normally no thinning is required. Under extreme conditions, consult your local representative for application advice. Do not thin beyond the limits of local environmental regulations.
Recommended nozzle size 0.38–0.46 mm (15–18 thou); total fluid output pressure at the nozzle not less than 176 kg/cm² (2500 psi)
Suitable.
Use suitable dedicated equipment. Thinning may be required.
Flush all equipment thoroughly with International thinner. All unused paint must be stored in tightly closed containers. Partly filled containers may show skinning and/or increased viscosity after storage. Strain the paint before use.
If welding or flame cutting is performed on metal coated with this product, dust and fumes will be released; use suitable personal protective equipment and local exhaust ventilation. In North America, follow the instructions in ANSI/ASC Z49.1 “Safety in Welding and Cutting”.
All work related to the application and use of this product must comply with national health, safety and environmental protection standards and regulations.
Before using this product, obtain, read and follow the health and safety information in the Material Safety Data Sheet for the product. Read and observe all precautions in the Material Safety Data Sheet and on the container label. If these warnings and requirements are not fully understood, or cannot be strictly observed, do not use the product. During application and drying of the product, provide adequate ventilation and protective measures to keep solvent vapour concentrations within safe limits, so as to prevent poisoning or oxygen deficiency. Take protective measures to avoid skin and eye contact with the product (e.g. gloves, goggles, face shield, barrier cream). Specific safety measures depend on the application method and working environment.
Emergency contact: USA/Canada — medical 1-800-854-6813; Europe — tel. (44) 191 4696111, hospital and doctor (44) 207 6359191; China — tel. (86) 532 83889090; other regions — contact the regional office.
Interlac 497 is not suitable for immersed areas.
Apply in good weather. The temperature of the surface to be coated must be at least 3 °C above the dew point. Unless otherwise specifically instructed, raise the paint temperature to between 21 and 27 °C before mixing and application to achieve optimum application performance. Unmixed paint (in sealed containers) must be stored protectively as specified in the Storage section of this product data sheet. The technical and application data given here are intended as general guidance for establishing an application procedure. Test results are obtained in a controlled laboratory environment, and International Paint does not claim that the published test results, or any other test results, accurately represent results obtained in all site environments. Because application, environmental and design parameters vary widely, care must be exercised in coating selection, performance verification and use.
Recoat data are for guidance only and depend on local climatic and environmental conditions. For specific advice, consult your local International Paint representative.
| Packaging Specifications | Component A volume; packaging |
|---|---|
| 20 L | 20 L; 20 L |
| 5 L | 5 L, 5 L. For other pack sizes, contact International Paint. |
| Packaging Specifications | Packaging weight |
|---|---|
| 20 L | 29.08 kg |
| 5 L | 7.31 kg |
| Shelf life | At 25 °C, minimum 24 months. Thereafter, re-inspection is required. Store in a dry, sheltered place away from heat and sources of ignition |
|---|
Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.
Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.
In-house item numbers for Interlac 497 Alkyd Intermediate Coat are as follows.Item No.is the most accurate form when ordering;Colour/colour codecorresponds to the actual colour (RAL, GSB are colour chart codes);Packaging SpecificationsFactory complete-set specification format. Colors not listed may be ordered against the colour card.
| Item No. | Colour / colour code | Packaging Specifications |
|---|---|---|
| CRB000 White | — | 20 L |
This model has a total of1item numbers, all listed on this page; colours outside the table (including special colours and bulk packaging) can be confirmed by phone, delivery dates are advised according to the factory's current production schedule and stock. In the packaging specification, the "+" indicates the complete-set notation for two-component products (base + curing agent), subject to the factory specification; a "—" in the colour column denotes an auxiliary product, or that the item has no colour code in the factory system.