China-based coatings exporter — industrial & marine protective coatings from China's production bases

Ceilcote 68 Lining

Quick Specs

Ceilcote 68 Lining is an epoxy coating. A reinforced lining for the protection of tanks, trenches and pits, particularly suitable for thickeners, clarifiers and other cracked concrete exposed to chemicals. A glass fibre reinforced epoxy lining system designed to protect concrete and carbon steel surfaces from chemical attack in immersion environments. When such problems occur, the surface must be covered to avoid sunlight exposure and/or application carried out in the cooler evening or night, so that air escape from the concrete does not occur during initial curing.

Parameter source: AKZONOBEL original technical data sheet (TDS) “Ceilcote 68 Lining”; spreading rate and other values converted from TDS parameters, for selection reference only.
The above content is compiled from the manufacturer's datasheet and this site's parameter tables. For selection, coating systems and lead times, pleaseContact Usfor confirmation.

This page carries the full TDS for this product, translated from the manufacturer's original document. No file download is needed; for an original-language copy, send an enquiry.

Volume Solids—
Dry Film Thickness—
Theoretical Spreading Rate—
VOC0.54 lb/gal (65 g/L) US EPA Method 24 for further…
Density / Specific Gravity1.08 kg/L (9.0 lb/gal)
Number of Components—
ThinnerDo not thin
Mixing Ratio3 parts : 1 part (by volume)
GlossN/A

Browse Similar Models by CategoryThis model belongs to: Epoxy

FAQ

What is the mixing ratio of Ceilcote?
Ceilcote mixing ratio is 3 parts : 1 part (by volume).
What is the typical thickness of Ceilcote?
Typical thickness of Ceilcote: base coat: (resin + powder) a 1550 micron (62 mils) wet film corresponds to a 1500 micron (60 mils) dry film; the theoretical spreading rate of the resin is 1.34 m²/L (55 ft²/US gal). The spreading rate of the powder is 2.4 kg/m².
What is the volume solids of Ceilcote?
Volume solids of Ceilcote is although the components are 100% reactive, actual volume solids depend on application conditions. Recommended calculated volume solids value is 97%.
What is the VOC of Ceilcote?
VOC of Ceilcote is 0.54 lb/gal (65 g/L) US EPA Method 24 for further…
What is the gloss of Ceilcote?
The gloss of Ceilcote is not applicable.
What thinner is used for Ceilcote?
Recommended thinner for Ceilcote: do not thin.
How is Ceilcote applied?
Application method for Ceilcote: float application, roller and airless spray; drying time and recommended topcoat recoating interval; surface preparation and the coating system are as described on this page.
Which standards apply to Ceilcote?
As recorded in the technical data on this page: before painting, all surfaces shall be assessed and prepared in accordance with ISO 8504-2000; ISO 8501 (see the application instructions on this page). Specific applicability is subject to the manufacturer's technical data sheet and the coating system.
Where can Ceilcote be purchased?
RichTech Industrial Technology (Shanghai) Co., Ltd. distributes industrial and marine coatings, representing brands including JOTUN, HEMPEL, International, PPG and KANSAI, and provides product selection, coating systems and quantity calculations. Company address: Changhui Building, 799 Yinxiang Road, Jiading District, Shanghai.

Product description

A glass fibre reinforced epoxy lining system designed to protect concrete and carbon steel surfaces from chemical attack in immersion environments.

Intended use

A reinforced lining for the protection of tanks, trenches and pits, particularly suitable for thickeners, clarifiers and other cracked concrete exposed to chemicals.

Application data

CEILCOTE Colour Grey 68 LINING

GlossN/A
Volume SolidsAlthough the components are 100% reactive, actual volume solids depend on application conditions. Recommended calculated volume solids value is 97%.
Typical thicknessBase coat: (resin + powder) 1550 µm (62 mil) wet film equivalent to 1500 µm (60 mil) dry film, theoretical spreading rate of resin 1.34 m²/L (55 ft²/US gal). Spreading rate of powder 2.4 kg/m² (0.5 lb/ft²) fabric reinforcement (resin-wetted fabric): 800 µm (32 mil), theoretical spreading rate 1.22 m²/L (50 ft²/US gal). Fabric usage 1.1 × surface area. Topcoat: various topcoat designs obtainable by roller or spray application of Ceilcote products, selected according to the target service environment. For specific topcoat types and number of coats consult the International Protective Coatings Ceilcote representative.
Practical Spreading RateAllow appropriate loss factor. Spreading rate will vary depending on the system and the condition of the surface to be coated; for further information refer to the relevant application instructions and coating scheme.
Application MethodsTrowel, roller, airless spray drying time recommended topcoat recoating interval
TemperatureSurface DryHard DryMinimumMaximum
10°C (50°F)12 h4 days24 h4 weeks
23°C (73°F)8 h24 h10 h4 weeks
30°C (86°F)6 h16 h6 h2 weeks

Regulatory compliance data

Flash point (typical)Component A 93 °C (199 °F); Component B 107 °C (225 °F); mixed 93 °C (199 °F)
Product weight1.08 kg/L (9.0 lb/gal)
Volatile Organic Compounds0.54 lb/gal (65 g/L) US EPA Method 24 for further details, see the "Product Characteristics" section

Surface Preparation

All surfaces to be painted must be clean, dry and free of contaminants. Before painting, all surfaces must be assessed and prepared in accordance with ISO 8504:2000.

Oil and grease removed in accordance with SSPC-SP1.

Steel substrate when used in immersion or wet environments or high-temperature environments, the product shall be applied to surfaces blast cleaned to Sa3 (ISO 8501-1:2007), SSPC SP5 or NACE #1. When used in dry environments, shall be applied to surfaces blast cleaned to Sa2½ (ISO 8501-1:2007), SSPC SP10 or NACE #2. Surface roughness minimum 75 µm (3 mil). The substrate must be applied with a 50–125 µm (2–5 mil) wet film of Ceilcote 680M.

Prior to application of Ceilcote 68 Lining on concrete substrates, the concrete surface shall be fully cured. The concrete surface shall be dry and tested by the plastic sheet method (ASTM D4263). All surfaces to be coated shall be clean, dry and free from accelerators, release agents, grease, oil, old coatings and loose or spalling concrete. All concrete surfaces to be coated must also be abrasive blast cleaned to obtain a roughened surface and remove laitance. Surface tensile strength (ASTM 4541) minimum 2 MPa (300 psi). For further information refer to the concrete surface preparation specification. The substrate must be applied with a 50–125 µm (2–5 mil) wet film of Ceilcote 680M.

Application

MixingCeilcote 68 Lining must be mixed and applied in accordance with the detailed application instructions of the subsequent system.

The resin component is supplied as two cans per unit. Normally the whole unit is mixed. Once mixed, it shall be used within the specified pot life. (1) Shake Component A, then pour the whole cans of Component A and Component B together and mix thoroughly with a power stirrer. (2) Component C, the powder component, shall be added slowly while Components A and B are being stirred. For specific quantity requirements, refer to the product data section.

Mixing ratio3 parts : 1 part (by volume)
Pot life10°C (50°F)23°C (73°F)30°C (86°F)
60 min30 min20 min
Suitable for airless sprayApplicable
Roller applicationApplicable
Trowel applicationApplicable
ThinnerDo not thin
CleanerCeilcote T-410 Solvent or MEK
Interruption of workDo not leave paint in equipment. Mixed paint should not be resealed. If work is suspended for an extended period, use freshly mixed paint when work resumes.
CleaningClean all equipment with T-410 solvent (or MEK) after application. All remaining material and empty containers shall be disposed of in accordance with local laws/regulations.

Product Characteristics

Prior to use of the relevant Ceilcote system, refer to the detailed Application Instructions. Application of Ceilcote 68 Lining requires that the application company's personnel have completed full application training. It is strongly recommended that both applicators and application supervisors be professionals trained in the correct product.

Before work begins, International Paint provides a precise system for dry film thickness and number of coats.

The surface temperature must be at least 3 °C (5 °F) above the dew point. Ensure adequate ventilation during application and curing. Dehumidification, air conditioning and/or heating equipment may be necessary to control the environment.

At all stages of application, the surface, air and paint temperatures must be between 10 °C (50 °F) and 43 °C (110 °F).

When applying outdoors or in sunlight, “bubbling” may occur as the surface temperature rises due to sunlight or ambient temperature. This can cause bubbles or pinholes in the applied flooring, lining or coating. When this occurs, shade the surface from sunlight, and/or apply in the cooler evening or at night, so that air does not escape from the concrete during initial cure. For more detailed advice, consult the International Paint Protective Coatings division.

Ceilcote 68 Lining maximum continuous dry temperature is 93 °C. Maximum continuous immersion temperature resistance of the product is 71 °C (160 °F) for concrete and 60 °C (140 °F) for steel.

Application1. Trowel apply one coat of 1000–2000 µm (40–80 mil) base coat (target 1500 µm, 60 mil).2. Press the reinforcement into the base coat, leaving no wrinkles or voids, wet the reinforcement with resin until the reinforcement becomes transparent.3. After curing apply the topcoat.4. Allow the topcoat to cure.

Various Ceilcote products can be selected as topcoat; specifically depending on the target service environment. For selection of specific topcoat products consult the International Ceilcote representative.

Note: VOC values are typical and for guidance only. They may vary with colour and general production tolerances.

Although the low-molecular-weight reactive additive becomes part of the film when cured under normal ambient conditions, analysis by EPA Method 24 shows that it also affects the VOC value.

System compatibility

Ceilcote 68 Lining shall always be applied to a correctly prepared primer surface. Suitable primers are as follows:

Ceilcote 680 PrimerCeilcote 680MCeilcote 690Typical topcoats are:
Ceilcote 600 FlakelineCeilcote 600HB Flakeline
Ceilcote 662 FlakelineCeilcote 664 Ceilgard

Supplementary information

For further information on the industry standards, terms and abbreviations used in this datasheet, see www.international-pc.comIn the following documents on the website: • Definitions and abbreviations • Surface preparation • Coating application • Theoretical and practical spreading rate. These sections are available on request.

Safety precautions

This product is intended for application only by professional applicators in the industrial sector, in accordance with the recommendations in this manual, the Material Safety Data Sheet and on the container packaging. Do not use this product without first reviewing the Material Safety Data Sheet (MSDS) that International Paint provides for its customers.

All work related to the application and use of this product must be carried out in accordance with the relevant national health, safety and environmental standards and regulations.

If welding or flame cutting is required on metal coated with this product, dust and fumes will be generated; use appropriate personal protective equipment and adequate local ventilation.

If in doubt about the suitability of this product, consult International Paint.

Packaging Specifications

Packaging SpecificationsComponent AComponent B
VolumePackagingVolumePackaging
4 US gal3 US gal5 US gal1 US gal

For other available packaging sizes, contact International Paint.

Shipping weight

Packaging SpecificationsComponent AComponent B
4 US gal31 lb9 lb

Storage

Shelf life18 months at 23°C (73°F). Inspection is required thereafter. Store in a dry, cool environment, away from heat and ignition sources.

© 2015/2/5 AkzoNobel. All rights reserved.

All registered trademarks mentioned in this publication are licensed to or owned by AkzoNobel.

www.international-pc.com

Information is subject to the manufacturer's latest version; the manufacturer's latest TDS prevails.
The technical parameters on this page are taken from the product's original manufacturer technical datasheet, the copyright of which belongs to the manufacturer. If a rights holder considers the presentation inappropriate, contact us for verification and handling.

Similar models from the same brand — epoxy coating

View all AKZONOBEL models

Purchase & Documents

Packaging specifications and batch lead times are subject to actual availability. PleaseContact Uscontact us for project-based calculation.

China production baseIndustrial & marine coatingsWorldwide delivery